跳转到主要内容
logo

Full range of Dayu ultrasonic measurement instruments

97 products

ImageModel / Name
Accuracy
Beam Angle
Output Type
Startup Delay
Detection Range
Housing Material
Operating Voltage
Output Cable Length
Storage Temperature
Transducer Frequency
Dead Zone(Blind Zone)
Operating Temperature
Repeatability Accuracy
Output Connection Method
Rated Operating Current Ie
Protection Rating(IP Rating)
Fastest Response Time (Active Upload)
Material
Supply Voltage
Measuring Range
Standard
Standard_2
Standard_3
Cable Length
Rated Current
Frequency Range
Operating Pressure
Transducer Material
Transducer Interface
Test Bracket Material
Transducer Protection Rating
Main Unit Dust Protection Rating
Weight
Interface
Turbidity
Data Types
Local Cache
Product Name
Channel Types
Local Display
Cable Material
Test Rod Length
Battery Capacity
Power Consumption
Test Rod Material
Acidity/Alkalinity
Cable Construction
Flow Meter Material
Totalized Flow Range
Communication Protocol
Handheld Unit Material
Operating Power Supply
Temperature Resolution
Flow Velocity Resolution
Instantaneous Flow Range
Totalized Flow Resolution
Field Flow Velocity Accuracy
External Sensor Voltage Range
Flow Velocity Measuring Range
Instantaneous Flow Resolution
Pressure Water Depth Accuracy
Handheld Unit Protection Rating
Pressure Water Depth Resolution
Verified Flow Velocity Accuracy
Pressure Water Depth Measuring Range
Response Time
Bit Error Rate
Protection Rating
Communication Rate
Transmitted Content
Communication Method
Storage Requirements
Operating Environment
Communication Distance
Power Supply and Power Consumption
Wiring Definition for Standard Sensors
Wiring Color Description for Acoustic Release
Output Connection
Measurement Accuracy
Display Mode
Control Cable
Output Signal
Operating Mode
No-load Current
Full-load Current
Operating Frequency
Cable Outer Diameter
Sensor Connection Method
Transducer Extension Cable Outer Diameter
Transmitter/Receiver Transducer Extension Cable
Red LED
Yellow LED
No-Load Current
Relay Switch Output
Control Cable Length
Control Connection Type
Hysteresis
Resolution
Setting Range
Output Type_2
Output Type_3
Output Type_4
Output Type_5
Start-Up Delay
Indicator Light
Indicator Light_2
Transducer Thread
Protection Rating (IP Rating)
Green LED
Standards
Dead Zone (Blind Zone)
Red Wire
Blue Wire
Gray Wire
Pink Wire
Brown Wire
Green Wire
White Wire
Yellow Wire
Response Delay
Sensor Housing
Turn-off Delay
Sensor Connection
Through-beam Distance
NPN Output Load Current
24V No-load Power Consumption
24V Full-load Power Consumption
Cable Length Between Control Box and Field Device
Cable Length Between Receiving Sensor and Control Box
Cable Length Between Transmitting Sensor and Control Box
Cable Outer Diameter Between Control Box and Field Device
Cable Outer Diameter Between Receiving Sensor and Control Box
Cable Outer Diameter Between Transmitting Sensor and Control Box
Cable
Power Supply
Standard Type
Flow Rate Range
Measurement Types
Water Depth Accuracy
Flow Velocity Accuracy
Sediment Concentration
Water Depth Resolution
Flow Velocity Accuracy_2
Flow Velocity Meter Material
Telemetry Terminal Main Unit Material
Enhanced Type Pressure Water Depth Measuring Range
Enhanced Type Ultrasonic Water Depth Measuring Range
Testable Transducer Frequencies
Echo Amplification Gain Selection
Probe Cable
Analog Output
Digital Output
Ambient Temperature
Storage Interval
Parameter Setting
Power Supply Mode
Temperature Range
Reporting Interval
Data Acquisition Interval
Data Acquisition Interface
Operating Ambient Humidity
Operating Ambient Temperature
Radar Level Meter - Measuring Range
Probe Material
Cable Specification
Structural Configuration
Overall Power Consumption
Pressure Resistance Rating
Measuring Range Specifications
Contact Capacity
Connection Method
Protection Circuit
M45 Underwater Obstacle Avoidance Sensor
M45 Underwater Obstacle Avoidance Sensor

M45

2cm±0.5% D (D refers to the measured range)9.7° ±1° °RS-485 (Modbus RTU protocol)<2000ms (software delay for protection) ms0.4~50m m304 stainless steel10.8V~26.4VDC, reverse polarity protection VDCDefault 5m (other lengths customizable) m-20~60°C °C300K K0.4m m-20~60°C °CD±0.25% (D refers to the measured range)Direct cable lead-out≤100mA mAIP68 (pressure resistant to 50m)250ms / cycle ms
M50 Underwater Obstacle Avoidance Sensor (Hydrological Customization)
M50 Underwater Obstacle Avoidance Sensor (Hydrological Customization)

M50

2cm±0.5% D (D Refers to the Measured Range)9.7° ±1° °RS-485 (Modbus RTU Protocol)<2000ms (Software Delay Protection) msDefault 5m (Other Lengths Available on Custom Order) m-20~60℃ ℃300K K0.4cm cm-20~60℃ ℃D±0.25% (D Refers to the Measured Range)4-Core Cable Outlet / Aviation Connector Outlet≤100mA mAIP68 (Pressure Resistant to 50m)250ms / cycle ms/cycleStainless Steel 31610.8V~26.4VDC, Reverse Polarity Protection VDC0.4m~50m m
Sound Velocity and Sound Attenuation Measuring Instrument
Sound Velocity and Sound Attenuation Measuring Instrument

Sound Velocity and Sound Attenuation Meter

RS-485 (Modbus RTU Protocol) Type-C Interface-40~+80℃ ℃-20~+60℃ ℃85VAC~305VAC (50Hz/60Hz) VACGB/T 15261-2008YY/T 0299-2022GB/T 18022-2000Standard 1m (Other cable lengths require customization) m500mA mA1~8 MHz (Default: 3.1MHz) MHz1 Standard Atmosphere standard atmosphereABSBNC RF ConnectorAluminumIP68IP6X
Portable Ultrasonic Doppler Flowmeter
Portable Ultrasonic Doppler Flowmeter

Portable Ultrasonic Doppler Flow Meter

-25~80℃ ℃-5~60℃ (non-freezing conditions) ℃IP68Standard 10m (other lengths available upon customization) m8.52kg±0.1kg kgType-C≤10NTU cannot be measured NTUWater level, flow velocity, temperature, instantaneous flow, totalized flow30000 records recordsPortable Ultrasonic Doppler Flow MeterCircular, rectangular, trapezoidal, irregular channels3.5-inch LCD backlit displayPUStandard 2.5m (0.5m*5) m3.6V/5200mAH600mAH (at 25℃ ambient temperature, can operate continuously for 6 hours) mAH304 stainless steelpH value between 6~104-core (single core 0.21m²) shielded cable with built-in air tube, outer diameter 8mmPOM+(ABS+PC)0.1m³~34560000000m³ m³Modbus RTUABS3~5VDC (3.6V lithium battery) VDC0.01℃ ℃1mm/s mm/s1m³/h~720000000m³/h m³/h0.001L L±1%~±3% (measurement accuracy varies with on-site working conditions) %10~24VDC VDC±0.03m/s~5m/s m/s0.001 m³/s m³/s±30mm mmIP653mm mm±(V*%1+0.01)m/s (accuracy verified by the Hydrological Verification Center)0.02~10m m
Ultrasonic Underwater Communication Sensor
Ultrasonic Underwater Communication Sensor

Ultrasonic Underwater Communication Sensor

180° °0~+60°C °C1500g±30g (including 10m cable weight) g3s s≤8% (depending on operating environment and sensor angle) %IP68 (withstands water depth up to 100 m)96bps (Maximum) bpsHexadecimal values corresponding to 1-12 ASCII charactersHalf-duplex, RS-485 (Modbus RTU Protocol)-20~+60°C, environment free of corrosive liquids and gasesWater depth greater than 2 m; keep away from motors and variable-frequency equipment100m m12VDC±10% (powered by battery or DC linear power supply); power consumption is 1W in receiving mode and 3.5W in transmitting modeRed — 12V positive; Black — 12V negative; Blue — 485A; Yellow — 485BRed — 12V positive; Black — 12V negative; Blue — 485A; Yellow — 485B; Green and White — relay contacts (contact rating: 1.5A/30VDC)
M33 Patch Underwater Obstacle Avoidance Sensor
M33 Patch Underwater Obstacle Avoidance Sensor

M33

2.1°±0.5% 4.6°±0.5% 7.8°±0.4%RS-485 (Modbus RTU Protocol)<2000ms (Software Delay Protection) ms0.05~3m 0.05-8m 0.05~10m m10.8V~26.4VDC, Reverse Polarity Protection VDCDefault 2m (other lengths available on request) m-20~+60°C °C2MHz 1MHz 800kHz0.05m 0.05m 0.05m m-20~+60°C °C0.25%D (D refers to the measured range)≤100mA mAIP68 (pressure resistant to 50m)100ms/time 115ms/time 115ms/timeAluminum Alloy78g (2m cable) 85g (2m cable) 85g (2m cable)4-core shielded cable, direct lead-out0.02m±0.5%D (D refers to the measured range)
M33 Underwater Obstacle Avoidance Sensor
M33 Underwater Obstacle Avoidance Sensor

M33

19.4°±1.9°|4.6°±0.5°RS-485 (Modbus RTU protocol)≤2000ms (software delay for protection) ms0.25~20m|0.1~8m10.8V~26.4VDC, reverse polarity protection VDCDefault 2m (other cable lengths require customization) m-20~+60℃ ℃300K|1MHz0.25m|0.1m-20~+60℃ ℃0.25%D (D is the measured range)Direct cable outlet≤100mA mAIP68 (pressure-resistant to 50m)140ms/cycle|115ms/cycleAluminum alloy118g (2m cable)|113g (2m cable)0.02m±0.5%D (D is the measured range)
Single/Double Sheet Detection Sensor (Dedicated to Label Measurement)
Single/Double Sheet Detection Sensor (Dedicated to Label Measurement)

Single/Double Sheet Detection Sensor (for Label Measurement)

Transducer mounting distance: 0.03~0.08 m; ideal value 0.045~0.06 m mPOM (transducer), ABS (control box)24 VDC (±10%) VDCLED display 0: empty / no paper LED display 1: single sheet or no label LED display 2: double sheets or label present1.5m (default) m3 NPN switching outputsThrough-beam≤80mA mA3×100mA200kHz±10% kHz5.3mm±0.3mm mmTransducer thread M18*1.52mm±0.03mm mm2m m
Ultrasonic Single-Channel Externally Mounted Liquid Level Switch (New Model)
Ultrasonic Single-Channel Externally Mounted Liquid Level Switch (New Model)

Ultrasonic Single-Channel Externally Mounted Liquid Level Switch (New Model)

ABS-20~+60°C °C1MHz, 2MHz-10~+55°C °C24VDC (±10%) VDCUltrasonic Single-Channel Externally Mounted Liquid Level SwitchRelay Alarm IndicatorPower Indicator (Steady On)≤30mA mAOptional 2 SPST (Single-Pole Single-Throw) relays; Contact Rating: AC 250V/5A or DC 28V/5A; Normally Open by Default1.5m by Default (Other Lengths Available on Request) mGX16 4-Pin Connector
Dedicated Sensor for Cattle Detection in Pastures
Dedicated Sensor for Cattle Detection in Pastures

Dedicated Sensor for Pasture Cattle Detection

85° °NPN switching output, normally open (voltage drop: ≤3.5 V)≤300 ms ms24 VDC ±10%, reverse polarity protection-40°C~+80°C °C40 kHz kHz0.25m m-20°C~+60°C °C0.25%FS %FS≤100 mA mAIP68ABS housing0.25~3m m<300 g (excluding cable) g±0.5% FS or ±0.03m (whichever is greater)≤25 mA mA3% of the set switching distance0.001m m0.25~3m m
M30 Ultrasonic Distance Measurement Sensor
M30 Ultrasonic Distance Measurement Sensor

M30

4~20mA analog output (load ≤500R at 24VDC)-40~+85°C °C-20~+60°C °C0.25%FS %FS≤100mA mAHousing: 304 stainless steel; Transducer: ABS24VDC±10%, with reverse polarity protection VDC0.2~6m mGB/T 14048.10-2016GB/T 14048.19-20132m by default (other lengths available on request) m<250g (excluding cable) gM12 8-pin connector±0.5%FS or ±0.03m (whichever is greater)≤25mA mA3% of the set switching distance %0.001m m0.2~6m m0~10V analog output (load ≥1k)NPN switching output, normally open (voltage drop: ≤3.5V)PNP switching output, normally openStandard RS-485 output (Modbus RTU protocol)≤300ms msGreen LED, analog output status indicator: steady on within range, flashes when out of rangeYellow LED, switching output indicator: steady on when conductingM30*1.5IP67
M18 Ultrasonic Distance Measurement Sensor
M18 Ultrasonic Distance Measurement Sensor

M18

4~20mA Analog Output (Load capacity varies with supply voltage: 10VDC load ≤250R; 28VDC load ≤500R) 0~10V Analog Output (Supply range for this output: 12V~30V, load ≥1k) NPN Switching Output, Normally Open (Voltage drop: ≤3.5V) PNP Switching Output, Normally Open (One of the above 4 options selectable) RS-485 (Modbus RTU Protocol)≤300ms ms0.06~1m m10V~30VDC, Reverse Polarity Protection VDCDefault 2m (Other cable lengths require customization) m-40~+85℃ ℃200kHz kHz0~0.06m m-20~+60℃ ℃0.25%FS %FSM12 8-pin Connector≤100mA mAIP67Housing: Stainless Steel + High-Transparency PC<100g (excluding cable) g±0.5%FS or ±0.03m (whichever is greater)Switching/Analog Output Range Indicator Light≤25mA mA3% of the set switching distance0.001m m0.06~1m mM18×1.0Power Indicator LightGB/T 14048.10-2016 GB/T 14048.19-2013
M70 High-Pressure Resistant Distance Measurement Sensor(Titanium Alloy Material)
M70 High-Pressure Resistant Distance Measurement Sensor(Titanium Alloy Material)

M70

2cm±0.5% D (D refers to the measured range)4.6°±0.5° °RS-485 (Modbus RTU protocol)<2000ms (software delay for protection) msDefault 2m (other lengths available upon customization) m-20~60°C °C1MHz MHz-20~60°C °CD±0.25% (D refers to the measured range)4-core cable outlet / aviation connector outlet≤100mA mA115ms / cycle msTitanium alloy10.8V~26.4VDC, reverse polarity protection VDC0.1m~8m mIP68 (pressure resistant to 2000m)0.1m m
M30 Wood Panel Bulging Sensor-Non-Corrosion-Resistant Type
M30 Wood Panel Bulging Sensor-Non-Corrosion-Resistant Type

M30

IP65DC 18V~30V V350g~770g (weight varies depending on internal configuration) g3-channel NPN outputThrough-beam; transmission power configurable via 485 bus<80mA mADC 24V power supply positiveRS-485 communication signal AWooden board detected between the through-beam probes, but no bulgeWooden board detected between the through-beam probes, with bulgeUltrasonic transmission power, host computer control signal (floating or high level = high-power transmission, low level = low-power transmission)DC 24V power supply negativeNo object detected; air between the through-beam probesRS-485 communication signal B15ms msNickel-plated brass (other materials available upon request)15ms msM30×1.5 threaded connection60~150mm; ideal value: 90~110mm mm<100mA mANo-load power consumption <2W WFull-load power consumption <9.2W W3000mm±300mm (customizable length) mm100mm~1300mm (customizable length) mm500mm~700mm (customizable length) mm5mm±0.03mm mm5mm±0.03mm mm5mm±0.03mm mm
Sewer ultrasonic Doppler flow meter
Sewer ultrasonic Doppler flow meter

Sewer ultrasonic Doppler flow meter

-25~80°C °C-5~60°C (non-freezing conditions) °CIP682.5kg (including 20m cable) kgSewer Doppler FlowmeterpH value between 6~10 pH0.01°C °C1mm/s mm/s0.03m/s~5m/s, -5m/s~-0.03m/s (customizable ±0.03m/s~±10m/s) m/s4G-CAT.1, NB-IoTStandard type: 4-core shielded cable, 4.5mm diameter; Enhanced type: 4-core shielded cable with air guide tube, 8mm diameter (default cable length 10 m; other lengths require customization)Supply Range: 5VDC~15VDC VDCThis model uses an external level meter; the level meter type and range are freely selected by the customer1 L/s ~ 99999999 m³/hFlow Velocity, Flow Rate, Water Temperature, Water Depth±3cm cm±(V*1%+0.01)m/s (accuracy verified by the Hydrological Verification Center) m/s20mg/L~20g/L3mm mm±1%~±3% (measurement accuracy varies depending on on-site working environment) %POM+(ABS+PC); Cable Material: PUPC+ABS or 304 Stainless Steel (choose one of the two)0.02~10m m0.08~3m (default: pressure depth measurement) m
Transducer test board
Transducer test board

Transducer test board

15VDC VDC15KHZ, 21KHZ, 25KHZ, 34KHZ, 40KHZ, 49KHZ, 64KHZ, 80KHZ, 100KHZ, 120KHZ, 150KHZ, 200KHZ, 250KHZ, 300KHZ KHZ1×, 10×, 100×, 1000× ×
Ultrasonic noise detection sensor
Ultrasonic noise detection sensor

Ultrasonic noise detection sensor

IP689VDC~36VDC VDC10mV mV4-core shielded cableSine Wave (sampled signal output at 10× and 100× amplification)RS485- 5°C ~60°C °C
Low-power radar manhole level meter
Low-power radar manhole level meter

Low-power radar manhole level meter

±3mm mmMain Unit Protection Rating: IP68 at 10m water depth, Radar Protection Rating: IP68 at 10m water depth12VDC VDCLow-Power Radar Manhole Level Meter≥100AH AH1mm mm1 minute-24 hours configurable minParameter setting via mobile phone BluetoothRechargeable lithium battery pack with independent sealed enclosure-40~+85℃ ℃1 minute-24 hours configurable min1 minute-24 hours configurable minN serial ports (Serial Port 1: RS232/RS485 selectable, Serial Port 2: RS485)0%~100%RH %RH-25℃~+55℃ ℃0~20m m
M30 Wood Board Bulge Sensor - Non-Corrosion-Resistant Type / Board Defect Detection / Wood Board Hollow Detection
M30 Wood Board Bulge Sensor - Non-Corrosion-Resistant Type / Board Defect Detection / Wood Board Hollow Detection

M30

M70 High-Pressure-Resistant Depth Sounder
M70 High-Pressure-Resistant Depth Sounder

M70

Sixteen-Beam Underwater Obstacle AvoidanceSensor. Detail Page_01.jpg
Sixteen-Beam Underwater Obstacle AvoidanceSensor. Detail Page_01.jpg

16-Beam Underwater Obstacle Avoidance Sensor (Split Type)

IP68 Ultrasonic Water Level Meter (3.6V power supply, ABS material)
IP68 Ultrasonic Water Level Meter (3.6V power supply, ABS material)

IP68

-40℃~+80℃ ℃-20℃~+60℃ ℃3.6VDC±0.2V VDCIP68 Ultrasonic Water Level Meter (3.6V)IP68 Rated for 10 m Water Depth±0.5%FS %FSNoneRS485 MODBUS-RTU ProtocolABS/PTFE Probe6.3mm Four-Core Shielded Cable mmNPT2"/G2A Thread≤15MA (Continuous Operation) mA≤1 Standard Atmosphere atm0.15-2m, 0.25-5m, 0.3-8m m
PCM80 Ultrasonic Ranging Sensor
PCM80 Ultrasonic Ranging Sensor

PCM80

1 SPST (Single Pole Single Throw) RelayABS24V±10% V-40℃~+80℃ ℃64kHz±5% kHz0.25m m-20℃~+60℃ ℃±0.25% FS % FSIP680.25~3.5m m370g gModbus RTU Protocol±0.03m or ±0.5% FS (whichever is greater)≤25mA mA0.001m m≤300ms msDC28V/5A (Default State: Normally Open)Six-core Cable, 2mReverse Polarity Protection, Transient Overvoltage Protection
Ultrasonic Doppler Flow Meter
Ultrasonic Doppler Flow Meter

Ultrasonic Doppler flowmeter