Application:road surface ponding measurement, domestic water tank level measurement, sanitation sprinkler water level measurement, swimming pool water level height measurement
Detection range:0.1~20m














| General Parameters | |
|---|---|
| Transducer Frequency | 300K | 1MHz |
| Blind Zone | 0.25m | 0.1 |
| Detection Range | 0.25~20m | 0.1~8 |
| Emission Angle | 19.4°±1.9° | 4.6°±0.5 |
| Fastest Response Time | 140ms/cycle | 115 ms/次 |
| Weight | 118g (2m cable) | 113g (2m cable) |
| Electrical Characteristics | |
| Operating Voltage | 10.8V~26.4VDC, Reverse Polarity Protection |
| Startup Delay | ≤2000ms (software delay for protection) |
| Output Characteristics | |
| Output Type | RS-485 (Modbus RTU Protocol) |
| Rated Operating Current Ie | ≤100 mA |
| Measurement Accuracy | 0.02m ±0.5%D (D is the measured range) |
| Repeatability Accuracy | 0.25%D (D is the measured range) |
| Ambient Temperature | |
| Operating Temperature | -20~+60 °C |
| Storage Temperature | -20~+60 °C |
| Mechanical Characteristics | |
| Output Connection Method | Direct Cable Outlet |
| Output Cable Length | Default 2m (other lengths require customization) |
| Protection Rating | IP68 (pressure resistant to 50m) |
| Material | Aluminum Alloy |
Send us your working conditions — engineers reply with selection advice and pricing within 24 hours.
Online 9:00-18:00 (Mon-Fri)