Application:water level ranging in glass sinks, liquid level ranging in small storage tanks, liquid level ranging in beakers, bottled liquid level ranging on production lines
Blind zone:0.06m
Measuring range:0.06~1m










| General parameters | |
|---|---|
| Blind zone | 0~0.06 m |
| Detection range | 0.06~1 m |
| Setting range | 0.06~1 m |
| Transducer frequency | 200 kHz |
| Indicator light | |
| Green LED | Power indicator light |
| Yellow LED | Switching/analog range indicator light |
| Electrical characteristics | |
| Operating voltage | 10V–30V DC, reverse polarity protection VDC |
| No-load current | ≤25 mA |
| Startup delay | ≤300 ms |
| Output characteristics | |
| Output type | 4–20mA analog output (load capacity varies with supply voltage; load ≤250R at 10VDC, ≤500R at 28VDC); 0–10V analog output (supply range for this output: 12V–30V, load ≥1k); NPN switching output, normally open (voltage drop: ≤3.5V); PNP switching output, normally open (choose one of the above 4); RS-485 (Modbus RTU protocol) |
| Rated operating current Ie | ≤100 mA |
| Resolution | 0.001 m |
| Measurement accuracy | ±0.5% FS or ±0.03m (whichever is greater) |
| Repeatability accuracy | 0.25%FS |
| Hysteresis | 3% of the set switching distance |
| Ambient temperature | |
| Operating temperature | -20~+60 ℃ |
| Storage temperature | -40~+85 ℃ |
| Mechanical characteristics | |
| Output connection method | M12 8-pin connector |
| Output cable length | Default 2m (other cable lengths require customization) |
| Transducer thread | M18×1.0 |
| Protection rating | IP67 |
| Weight | <100g (excluding cable) |
| Material | Housing: stainless steel + high-transparency PC |
| Compliance standard | |
| Standard | GB/T 14048.10-2016;GB/T 14048.19-2013 |
Send us your working conditions — engineers reply with selection advice and pricing within 24 hours.
Online 9:00-18:00 (Mon-Fri)