跳转到主要内容
logo

Full range of Dayu ultrasonic measurement instruments

97 products

ImageModel / Name
Weight
Sensitivity
Cable Length
Power Supply
Output Signal
Product Model
Connection Cable
Housing Material
Ambient Temperature
Pressure Resistance
Response Frequency Range
Overall Power Consumption
Protection Rating (IP Rating)
Thread
Material
Output Type
Product Name
Response Delay
Detection Range
No-load Current
Operating Voltage
Output Connection
Linearity Accuracy
Distance Resolution
Linearity Direction
Output Cable Length
Storage Temperature
Transducer Frequency
Dead Zone(Blind Zone)
Operating Temperature
Standard Target Plate
Repeatability Accuracy
Temperature Resolution
Protection Rating(IP Rating)
Beam Angle
Beam Angle_2
Beam Angle_3
Beam Angle_4
Sensor Model
Startup Delay
Measuring Range
Built-in Battery
Probe Connection
Main Unit Display
Measuring Range_2
Measuring Range_3
Measuring Range_4
M33 Sensor Material
Measurement Accuracy
Dead Zone (Blind Zone)
Transducer Frequency_2
Transducer Frequency_3
Transducer Frequency_4
Weight (with 5m cable)
Rated Operating Current
Dead Zone (Blind Zone)_2
Dead Zone (Blind Zone)_3
Dead Zone (Blind Zone)_4
Output Connection Method
Weight (with 5m cable)_2
Weight (with 5m cable)_3
Weight (with 5m cable)_4
Mounted Sensor Connection
Protection Rating (Probe)
Rated Sensor Power Supply
Protection Rating (Main Unit)
Handheld Unit External Power Supply
Fastest Response Time (Active Upload)
Fastest Response Time (Active Upload)_2
Fastest Response Time (Active Upload)_3
Fastest Response Time (Active Upload)_4
Resolution
Probe Cables
Response Time
Supply Voltage
Mounting Method
Number of Beams
Number of Probes
Power Consumption
Detection Distance
Measuring Accuracy
Main Unit Output Cable
Communication Interface
Control Cable
Operating Mode
Full-load Current
Installation Method
Sensor Connection Method
Extension Cable Length for Transmitting and Receiving Transducers
Housing Form
Detection Mode
Communication Protocol
Transducer Protection Rating
Accuracy
Probe Cable
Main Unit Cable
Weight (with 2m Cable)
Sensor Rated Power Supply
Handheld Unit External Power Output
Working Mode
Operating Frequency
Cable Outer Diameter
Transducer Extension Cable
Transducer Extension Cable Outer Diameter
Mounting Method_2
Overall Hydrophone Length
Overall Protection Rating with Cable
Selectable Output — Analog Output — *10 Output
Selectable Output — Analog Output — *100 Output
Selectable Output — RS-485 Output — Digital Output
Selectable Output — RS-485 Output — EN Trigger Acquisition
Analog Output
Digital Output
Probe Material
Average Current
Operating Pressure
Cable Configuration
Thread Specification
Output
Green Light
Yellow Light 1
Yellow Light 2
Container Diameter
Control Connection
Container Diameter_2
Control Cable Length
Controller
No-Load Current
Sensor Material
Operating Temperature (Sensor)
Operating Temperature (Controller)
Connection Type
Rated Operating Current Ie
Connecting Cable
Frequency Response
Selectable Output (Choose One) └ Analog Output ├ *10 Output
Selectable Output (Choose One) └ Analog Output └ *100 Output
Selectable Output (Choose One) ├ RS-485 Output ├ Digital Output
Selectable Output (Choose One) ├ RS-485 Output ├ EN Trigger Acquisition
Communication
Interface Type
Transducer Model
Transducer Beam Angle
Transducer Dimensions
Circuit Board Dimensions
Transducer Measuring Range
Probe Pressure Resistance Rating
Transducer Dead Zone (Blind Zone)
Transducer Protection Rating (IP Rating)
Transducer Fastest Response Time (Active Upload)
Type
Function
Relay (2-Wire)
Relay (4-Wire)
Display (2-Wire)
Display (4-Wire)
Resolution (2-Wire)
Resolution (4-Wire)
Probe Cable (2-Wire)
Probe Cable (4-Wire)
Power Supply (2-Wire)
Power Supply (4-Wire)
Analog Output (2-Wire)
Analog Output (4-Wire)
2-Wire Power Consumption
Measuring Range (2-Wire)
Measuring Range (4-Wire)
Protection Rating (2-Wire)
Protection Rating (4-Wire)
Probe Installation (2-Wire)
Probe Installation (4-Wire)
Measurement Accuracy (2-Wire)
Measurement Accuracy (4-Wire)
Communication Protocol (2-Wire)
Communication Protocol (4-Wire)
Communication Interface (2-Wire)
Communication Interface (4-Wire)
4-Wire Power Consumption (220VAC)
2-Wire Power Supply & Configuration
Ambient Temperature (2-Wire - Probe)
Ambient Temperature (4-Wire - Probe)
4-Wire Power Supply & Configuration (24VDC)
Ambient Temperature (2-Wire - Display Unit)
Ambient Temperature (4-Wire - Display Unit)
4-Wire Power Supply & Configuration (220VAC)
4-Wire Power Consumption (24VDC Optional: add two relays)
4-Wire Power Consumption (24VDC Standard: mA output only)
4-Wire Power Consumption (24VDC Optional: 485 output only)
4-Wire Power Consumption (24VDC Optional: both 485 and mA outputs)
Standard
Emission Angle
0~10V Output Load
Accessory Weight
Fastest Response Time
Output Connection Type
Connection Method
Protection Circuit
Output Type_2
Output Type_3
Setting Range
Indicator Light
Indicator Light_2
Indicator Light_3
Transducer Thread
Transducer Connection
Transducer Cable Length
M40 Pole Dual Probe Distance Measurement Sensor
M40 Pole Dual Probe Distance Measurement Sensor

M40

M24Hydrophone
M24Hydrophone

M24

≤120g (Including 0.2m Cable) g≥-150dB ± 3dB Vref: 1v/μPa0.2m mDC 5V~12 V VAnalog Output (Amplified 1000x / 60 dB)MENDF1-M24GS-MHSTwo-Core Shielded Cable316 Stainless Steel-20℃~+80℃ ℃≤3MPa MPa20Hz~20kHz Hz≤100mW mWIP68 (Waterproof to 300m)
NMM60 Ultrasonic Distance Measurement Sensor
NMM60 Ultrasonic Distance Measurement Sensor

NMM60

<260g (including 2m cable) gG1 1/2ABSRS-485 (Modbus RTU Protocol)NMM60 Ultrasonic Distance Sensor50ms ms200~3000mm mm≤25mA mA10~30VDC, Reverse Polarity Protection VDCM12-8 Pin Connector±1% %1mm mmPositiveDefault 2m m-40~80°C °C80kHz±2kHz kHz0~200mm mm-20~60°C °C100mm×100mm±0.5% %0.1°C °CIP67
Handheld Depth Sounder S20 Pro+M36 Underwater Obstacle Avoidance Sensor
Handheld Depth Sounder S20 Pro+M36 Underwater Obstacle Avoidance Sensor

Handheld depth sounder S20 Pro+M36 underwater obstacle avoidance sensor

RS-485 (Modbus RTU protocol)Default 5m (customizable) m-20℃~+60℃ ℃300kHz kHz-20℃~+60℃ ℃0.25%D (D refers to the measured range)19.4°±1.9% °10°±1% °4.6°±0.5% °2.1°±0.5% °M36 (304 stainless steel material)≤2000 ms ms0.3~20m mTwo 18650 cells in parallel3-pin aviation connectorLCD display0.4~50m m0.1~8m m0.05~3m m304 stainless steel0.02m ±0.5% D (D refers to the measured range)0.3m m300kHz kHz1MHz MHz2MHz MHz230g g≤100 mA mA0.4m m0.1m m0.05m m4-core cable outlet / aviation connector outlet230g g220g g220g g4-pin aviation connectorIP68, pressure-resistant to 150mDC 10~26.4 V VIP54DC 12~24 V, 100 mA V140ms/time ms/time300ms/time ms/time115ms/time ms/time110ms/time ms/time
Ten-Beam Ultrasonic Ranging and Obstacle Avoidance Sensor (Underwater)
Ten-Beam Ultrasonic Ranging and Obstacle Avoidance Sensor (Underwater)

10-beam ultrasonic distance measurement obstacle avoidance sensor (in water)

Main unit output cable, 5m as standardProbe IP68, main unit IP54 (main unit must be placed inside a sealed enclosure)-20℃ ~ +60℃ ℃0.15m m0.001m m10 probe cables, each connected to its corresponding interface≤300ms msDC 10.8~26.4V VSplit mounting (probe and circuit board separated)10 independent ultrasonic channels10 channels (cyclic detection of 1~10 directions available)<5W W2.5m (in water) m0.02m ±0.5% D (D refers to the measured range)4-core cable (power + communication)RS-485 (Modbus RTU protocol)
Ultrasonic Surface Flatness Detection Sensor
Ultrasonic Surface Flatness Detection Sensor

Ultrasonic surface flatness detection sensor

RS-485 (Modbus RTU Protocol)POM (Transducer), ABS (Control Box)Rubber, paper, metal, plastic, etc.<20mA mA24VDC(±10%) VDC-20~+60°C °C300kHz kHz-10~+60°C °C2m (Default) mThrough-beam<50mA mAAngled installation, parallel installationTransducer fitted onto fixed mounting fixture2m (Default) m
Non-metal Detector
Non-metal Detector

Non-metal detector

Plastic-20℃~+60℃ ℃DC 10.8~26.4V VMax. 10m (determined by reading echo signal) mFX custom housing / NC no housingOne-transmit-one-receive (pulse-echo)RS-485 (Modbus RTU protocol)IP68
Ten-beam Ultrasonic Distance Measurement Obstacle Avoidance Sensor (in air)
Ten-beam Ultrasonic Distance Measurement Obstacle Avoidance Sensor (in air)

10-beam ultrasonic distance measurement obstacle avoidance sensor (in air)

Main unit output cable: 5m standard mProbe IP66, main unit IP54-20℃ ~ +60℃ ℃0.03m±0.5% FS0.15m m0.001m m10 probe cables, each connected to its corresponding interface≤300ms msDC 10.8~26.4V VSplit mounting (probe separated from circuit board)10-channel independent ultrasonic channels10 channels (cyclic detection of 1~10 directions available) channels<5W W2.5m (in air) m4-core cable (power + communication) coresRS-485 (Modbus RTU protocol)
Sixteen-beam Ultrasonic Distance Measurement Obstacle Avoidance Sensor (Underwater)
Sixteen-beam Ultrasonic Distance Measurement Obstacle Avoidance Sensor (Underwater)

16-beam ultrasonic distance measurement obstacle avoidance sensor (in water)

Main unit output cable: 5m standard0.15m m-20℃~+60℃ ℃Probe IP68, main unit IP54 (main unit must be placed in a sealed enclosure)0.001m m≤500ms msDC 10.8~26.4V VSplit-type installation (probe and circuit board separated)16-channel independent ultrasonic16 channels (supports cyclic detection of 1~16 directions)<5W W2.5m (in water) m4-core cable (power + communication)RS-485 (Modbus RTU protocol)0.02m + 0.5% D (D refers to the measured range)16 probe cables, each connected to the corresponding interface
16-Beam Ultrasonic Distance Measurement Obstacle Avoidance Sensor (in Air)
16-Beam Ultrasonic Distance Measurement Obstacle Avoidance Sensor (in Air)

16-beam ultrasonic distance measurement obstacle avoidance sensor (in air)

Main unit cable standard 5m0.15m m-20℃~+60℃ ℃Probe IP66, main unit IP540.5% FS or ±0.03m (whichever is greater)0.001m m≤500ms msDC 10.8~26.4V VSplit mounting (probe separated from circuit board)16-channel independent ultrasonic16 channels (cyclic detection of 1~16 directions)<5W W2.5m (in air) mRS-485 (Modbus RTU protocol)16 probe cables, each connected to its corresponding interface4-core cable (power + communication)
Handheld Depth Sounder S20 Pro+M33 Patch Underwater Obstacle Avoidance Sensor
Handheld Depth Sounder S20 Pro+M33 Patch Underwater Obstacle Avoidance Sensor

Handheld depth sounder S20 Pro+M33 patch underwater obstacle avoidance sensor

RS-485 (Modbus RTU Protocol)Default 2m (Customizable) m-20°C~+60°C °C2MHz / 1MHz / 800kHz-20°C~+60°C °C0.25%D (D refers to the measured range)2.1°±0.5% / 4.6°±0.5% / 7.8°±0.4% °M33 SMD Type (Aluminum Alloy Housing)≤2000 ms ms0.05~3m / 0.05~8m / 0.05~10m mTwo 18650 Batteries in Parallel3-Pin Aviation ConnectorLCD DisplayAluminum Alloy0.05m m≤100 mA mA4-Core Shielded Cable with Direct Lead-Out4-Pin Aviation ConnectorIP68, Pressure Resistant to 50mIP54100ms/cycle / 115ms/cycle ms0.02m ±0.5% D (D refers to the measured range)78g / 85g gDC 10~26.4 V VDC 12~24 V, 100 mA V
Ultrasonic Crack Detection Sensor
Ultrasonic Crack Detection Sensor

Ultrasonic crack detection sensor

RS-485POM (transducer), ABS (control box)0.01~0.5m m<20mA mA-20~60°C °C-10~60°C °C24VDC(±10%) VDC2m (default) m<50mA mAThrough-beam1MHz±10% MHz0.0053m m2m (default) m0.003m m
M45 Leak Detection Hydrophone
M45 Leak Detection Hydrophone

M45

≤800g, Including 2m Attached Cable g≥ -160dB  Vre: 1V/μPa dB6VDC~13VDC VDCLow-Noise Four-Core Shielded Cable20Hz-20KHz Hz≤150mW (12VDC Supply) mW304 Stainless Steel HousingMagneticClamp Fixed96mm, Excluding Connection Cable mmIP68≥-180dB dB≥-160dB dBRS-485 (Modbus RTU Protocol)3.3V ~ 5V V
3.6V Micro-Power IP68 Ultrasonic Water Level Meter (NPT 2” Thread/ABS Material/Bluetooth Communication)
3.6V Micro-Power IP68 Ultrasonic Water Level Meter (NPT 2” Thread/ABS Material/Bluetooth Communication)

3.6V

IP683.6V Low-Power IP68 Ultrasonic Water Level Meter3VDC~5VDC VDC-40°C~80°C °C-20°C~60°C °C100KHz (0.15-1.5m) | 64KHz (0.25-5m) | 49KHz (0.3-8m)±0.5%FS %FS0.1V~2.6V (Available for MCU Direct Sampling) VRS485, TTL (ModBus-RTU Protocol)ABS≤3mA/3.6V (Instantaneous Current 7mA/3.6V)1 Standard Atmosphere Standard AtmosphereStandard 2m (Cable length greater than 2m is not recommended; the shorter the better)NPT 2 "
Ultrasonic dual-channel clamp-on liquid level switch
Ultrasonic dual-channel clamp-on liquid level switch

Ultrasonic dual-channel clamp-on liquid level switch

ABSUltrasonic Dual-Channel Externally Mounted Liquid Level Switch≤30mA mA24VDC(±10%) VDC-20~60°C °C-10~55°C °CMagnetic mounting / Clamp mounting / Adhesive mounting2-channel NPN (24V, 100mA)Power indicatorLights up when the first NPN channel is turned onLights up when the second NPN channel is turned on50mm-350mm, use 2MHz frequency transducer mmGX16 4-pin connector350mm-600mm, use 1MHz frequency transducer mm1.5m by default (other lengths available on request) m
Dual-channel split-type insertion ultrasonic liquid level switch
Dual-channel split-type insertion ultrasonic liquid level switch

Dual-channel split-type insertion ultrasonic liquid level switch

24VDC(±10%) VDCSensor IP68, Controller IP65Dual-Channel Split-Type Insertion Ultrasonic Level Switch-20~60℃ ℃≤60ms msSensor with fixed 1/4NPT thread (other mounting methods available upon request)≤2MPa MPaNPN/PNP/RelayDIN35 Rail Mounting13mA mATitanium AlloySensor -10~80℃ ℃Controller -20~60℃ ℃
Four-beam underwater obstacle avoidance sensor (split type)
Four-beam underwater obstacle avoidance sensor (split type)

Four-beam underwater obstacle avoidance sensor (split type)

Probe IP68 (pressure resistant to 150m)Standard RS-485 (Modbus RTU protocol), TTL output optionalFour-Beam Underwater Obstacle Avoidance Sensor (Split Type)-20~+60°C °C-20~+60°C °C0.25%D (D refers to the measured range)≤1000ms ms3m m0.01m±0.5%D (D refers to the measured range)0.15m m100ms/cycle (response time for active upload when polling four channels) ms10.8VDC~26.4VDC, with reverse polarity protection VDC4-core shielded cableAviation plug connector or direct cable outlet≤60mA (at 24V) mA
M26 Leak Detection Hydrophone
M26 Leak Detection Hydrophone

M26

≤350g, including 2m attached cable g≥ -160dB  Vre: 1V/ μPa dB6VDC~30VDC VDCHousing: 304 Stainless Steel3/4” Thread≤150mW (12VDC supply) mW76mm (excluding connecting cable) mmIP68Low-noise four-core shielded cable10Hz-20KHz Hz≥-180dB dB≥-160dB dBRS-485 (Modbus RTU Protocol)3.3V ~ 5V V
Road waterlogging sensor (split type) / road waterlogging, underpass waterlogging monitoring / road surface water level monitoring
Road waterlogging sensor (split type) / road waterlogging, underpass waterlogging monitoring / road surface water level monitoring

Road waterlogging sensor (split type) / road water accumulation, underpass water accumulation monitoring / road water level monitoring

1.5V~5V V-20℃~60℃ ℃±0.5% (Max. Measuring Range) %TTLModBus Standard ProtocolXH2.54 TerminalKDYW-1M-01U5.1°±10% °φ21mm*H13mm28mm*28mm2m in Clear Water m1MPa MPa0.02-0.03m mIP685 Times per Second times/s
Integrated Ultrasonic Level Meter
Integrated Ultrasonic Level Meter

Integrated Ultrasonic Level Meter

Integrated Ultrasonic Level MeterIntegrated Type2-Wire, 4-WireNoneOptional 2 SPST (Single Pole Single Throw) relays, AC250V/5A or DC 30V/5A; default state: normally openChinese/English LCD display (on-site echo display)Chinese/English LCD display (on-site echo display)1mm or 0.1% (whichever is greater)1mm or 0.1% (whichever is greater)NoneNoneStandard 24VDC±10% VDCStandard supply 24VDC±10%; optional 90~264VAC 50Hz; customizable 12VDC±10% or battery powered4~20mA / 250Ω load mA4~20mA / 510Ω load mA0.096~0.48W (4~20mA) W5m, 10m, 15m, 20m5m, 10m, 15m, 20m, 30m, 40m, 50mIP65IP65According to the measuring range and probe selectionAccording to the measuring range and probe selection0.5%~1.0% %0.5%~1.0% %Protocol: MODBUS RTU or manufacturer-customized protocolProtocol: MODBUS RTU or manufacturer-customized protocolInterface: RS-485 or RS-232 (optional)Interface: RS-485 or RS-232 (optional)5.0W W24VDC VDCProbe -20~+80℃ ℃Probe -20~+80℃ ℃24VDC VDCDisplay unit -20~+60℃ ℃Display unit -20~+60℃ ℃220VAC VACAdd 1.0W to the base power consumption W1.0W W0.6W W1.1W W
Ultrasonic dual-probe ranging sensor
Ultrasonic dual-probe ranging sensor

Ultrasonic dual-probe distance measurement sensor

<300g (excluding cable) gABSRS-485 (Modbus RTU Protocol)Ultrasonic Dual-Probe Distance Sensor0.05~2m m10~30VDC, Reverse Polarity Protection VDC-40~+80°C °C100kHz kHz0~0.05m m-20~+60°C °C0.25%FS %FSIP68≤100ms ms±0.5%FS or ±0.03m (whichever is greater)0.0005m mGB/T 38615-202011.7° ±5% °≥1kΩ kΩ
M36 Underwater Obstacle Avoidance Sensor (ABS material, aviation plug version)
M36 Underwater Obstacle Avoidance Sensor (ABS material, aviation plug version)

M36

151g (2m direct cable lead-out)|114g (net weight, connector type)|94g (net weight, connector type)|90g (net weight, connector type) gIP68 (pressure resistant to 150m)ABSRS-485 (Modbus RTU protocol)Default 2m (other cable lengths available upon customization) m-20~60°C °C300K|300K|1MHz|2MHz Hz-20~60°C °C±0.25% %<2000ms (software delay for protection) ms0.3~20m|0.4~50m|0.1~8m|0.05~3m m0.3m|0.4m|0.1m|0.05m m10.8V~26.4VDC, reverse polarity protection VDC0.02m±0.5% D (D refers to the measured depth)≤100mA mA19.4°±1.9°|10°±1°|4.6°±0.5°|2.1°±0.5° °5g g(Active Upload) 140ms / cycle|300ms / cycle|115ms / cycle|110ms / cycle ms/cycle4-core cable lead-out / connector lead-out
PCM60 Ultrasonic Ranging Sensor
PCM60 Ultrasonic Ranging Sensor

PCM60

235g gABSRS-485≤300ms ms0.2~3.5m m≤25mA mA24V±10% V-40℃~+80℃ ℃64kHz±5% kHz0.2m m-20℃~+60℃ ℃0.25%FS %FSIP68±0.5%FS or ±0.03m (whichever is greater)0.001m mModbus RTU protocolSix-core cable, 2mReverse polarity protection, transient overvoltage protection
Ultrasonic Dual-Channel Distance Measurement Sensor
Ultrasonic Dual-Channel Distance Measurement Sensor

Ultrasonic dual-channel distance measurement sensor

Approx. 500g gTransducer: PVDF; Housing: ABS2-Channel NPN Switching Output, Normally Open (Voltage Drop ≤2.5V)Ultrasonic Dual-Channel Distance Sensor0.15~1.5m mGX20 6-Pin ConnectorDefault 1 m (Other Cable Lengths Available on Request) m-40~+80℃ ℃100kHz kHz0~0.05m (Measuring Range: 1.5m) m-20~+60℃ ℃Transducer IP68, Main Unit Housing IP67≤300ms ms21.6VDC~26.4VDC, Reverse Polarity Protection VDC≤25mA mA≤100mA, Short-Circuit / Overload Protection mAGB/T 14048.10-20162-Channel PNP Switching Output, Normally Open (Voltage Drop ≤2.5V) (Optional, Choose One of Two)Standard RS-485 (Modbus RTU Protocol)0.15~1.5m mGreen LED: Power IndicatorYellow LED1: Channel 1 Probe IndicatorYellow LED2: Channel 2 Probe IndicatorNPT 1"GX12 3-Pin ConnectorDefault 1 m (Other Cable Lengths Available on Request) m