跳转到主要内容
logo

103 products

ImageModel / Name
Weight
Resolution
Output Type
Response Delay
Detection Range
No-load Current
Housing Material
Connection Method
Operating Voltage
Protection Circuit
Storage Temperature
Measurement Accuracy
Transducer Frequency
Dead Zone(Blind Zone)
Operating Temperature
Communication Protocol
Repeatability Accuracy
Protection Rating(IP Rating)
Material
Standard
Product Name
Output Type_2
Output Type_3
Setting Range
Startup Delay
Supply Voltage
Indicator Light
No-Load Current
Indicator Light_2
Indicator Light_3
Output Connection
Transducer Thread
Output Cable Length
Transducer Connection
Transducer Cable Length
Rated Operating Current Ie
Accuracy
Beam Angle
Output Connection Method
Fastest Response Time (Active Upload)
Measuring Range
Standard_2
Standard_3
Cable Length
Rated Current
Frequency Range
Operating Pressure
Transducer Material
Transducer Interface
Test Bracket Material
Transducer Protection Rating
Main Unit Dust Protection Rating
Interface
Turbidity
Data Types
Local Cache
Channel Types
Local Display
Cable Material
Test Rod Length
Battery Capacity
Power Consumption
Test Rod Material
Acidity/Alkalinity
Cable Construction
Flow Meter Material
Totalized Flow Range
Handheld Unit Material
Operating Power Supply
Temperature Resolution
Flow Velocity Resolution
Instantaneous Flow Range
Totalized Flow Resolution
Field Flow Velocity Accuracy
External Sensor Voltage Range
Flow Velocity Measuring Range
Instantaneous Flow Resolution
Pressure Water Depth Accuracy
Handheld Unit Protection Rating
Pressure Water Depth Resolution
Verified Flow Velocity Accuracy
Pressure Water Depth Measuring Range
Response Time
Bit Error Rate
Protection Rating
Communication Rate
Transmitted Content
Communication Method
Storage Requirements
Operating Environment
Communication Distance
Power Supply and Power Consumption
Wiring Definition for Standard Sensors
Wiring Color Description for Acoustic Release
Display Mode
Control Cable
Output Signal
Operating Mode
Full-load Current
Operating Frequency
Cable Outer Diameter
Sensor Connection Method
Transducer Extension Cable Outer Diameter
Transmitter/Receiver Transducer Extension Cable
Red LED
Yellow LED
Relay Switch Output
Control Cable Length
Control Connection Type
Hysteresis
Output Type_4
Output Type_5
Start-Up Delay
Protection Rating (IP Rating)
Green LED
Standards
Dead Zone (Blind Zone)
Red Wire
Blue Wire
Gray Wire
Pink Wire
Brown Wire
Green Wire
White Wire
Yellow Wire
Sensor Housing
Turn-off Delay
Sensor Connection
Through-beam Distance
NPN Output Load Current
24V No-load Power Consumption
24V Full-load Power Consumption
Cable Length Between Control Box and Field Device
Cable Length Between Receiving Sensor and Control Box
Cable Length Between Transmitting Sensor and Control Box
Cable Outer Diameter Between Control Box and Field Device
Cable Outer Diameter Between Receiving Sensor and Control Box
Cable Outer Diameter Between Transmitting Sensor and Control Box
Cable
Power Supply
Standard Type
Flow Rate Range
Measurement Types
Water Depth Accuracy
Flow Velocity Accuracy
Sediment Concentration
Water Depth Resolution
Flow Velocity Accuracy_2
Flow Velocity Meter Material
Telemetry Terminal Main Unit Material
Enhanced Type Pressure Water Depth Measuring Range
Enhanced Type Ultrasonic Water Depth Measuring Range
Testable Transducer Frequencies
Echo Amplification Gain Selection
Probe Cable
Analog Output
Digital Output
Ambient Temperature
Storage Interval
Parameter Setting
Power Supply Mode
Temperature Range
Reporting Interval
Data Acquisition Interval
Data Acquisition Interface
Operating Ambient Humidity
Operating Ambient Temperature
Radar Level Meter - Measuring Range
Probe Material
Cable Specification
Structural Configuration
Overall Power Consumption
Pressure Resistance Rating
Measuring Range Specifications
PCM60 Ultrasonic Ranging Sensor
PCM60 Ultrasonic Ranging Sensor

PCM60

235g g0.001m mRS-485≤300ms ms0.2~3.5m m≤25mA mAABSSix-core cable, 2m24V±10% VReverse polarity protection, transient overvoltage protection-40℃~+80℃ ℃±0.5%FS or ±0.03m (whichever is greater)64kHz±5% kHz0.2m m-20℃~+60℃ ℃Modbus RTU protocol0.25%FS %FSIP68————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————
Ultrasonic Dual-Channel Distance Measurement Sensor
Ultrasonic Dual-Channel Distance Measurement Sensor

Ultrasonic dual-channel distance measurement sensor

Approx. 500g g—2-Channel NPN Switching Output, Normally Open (Voltage Drop ≤2.5V)—0.15~1.5m m—————-40~+80℃ ℃—100kHz kHz0~0.05m (Measuring Range: 1.5m) m-20~+60℃ ℃——Transducer IP68, Main Unit Housing IP67Transducer: PVDF; Housing: ABSGB/T 14048.10-2016Ultrasonic Dual-Channel Distance Sensor2-Channel PNP Switching Output, Normally Open (Voltage Drop ≤2.5V) (Optional, Choose One of Two)Standard RS-485 (Modbus RTU Protocol)0.15~1.5m m≤300ms ms21.6VDC~26.4VDC, Reverse Polarity Protection VDCGreen LED: Power Indicator≤25mA mAYellow LED1: Channel 1 Probe IndicatorYellow LED2: Channel 2 Probe IndicatorGX20 6-Pin ConnectorNPT 1"Default 1 m (Other Cable Lengths Available on Request) mGX12 3-Pin ConnectorDefault 1 m (Other Cable Lengths Available on Request) m≤100mA, Short-Circuit / Overload Protection mA——————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————
M45 Underwater Obstacle Avoidance Sensor
M45 Underwater Obstacle Avoidance Sensor

M45

——RS-485 (Modbus RTU protocol)—0.4~50m m—304 stainless steel—10.8V~26.4VDC, reverse polarity protection VDC—-20~60°C °C—300K K0.4m m-20~60°C °C—D±0.25% (D refers to the measured range)IP68 (pressure resistant to 50m)——————<2000ms (software delay for protection) ms———————Default 5m (other lengths customizable) m——≤100mA mA2cm±0.5% D (D refers to the measured range)9.7° ±1° °Direct cable lead-out250ms / cycle ms——————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————
M50 Underwater Obstacle Avoidance Sensor (Hydrological Customization)
M50 Underwater Obstacle Avoidance Sensor (Hydrological Customization)

M50

——RS-485 (Modbus RTU Protocol)———————-20~60℃ ℃—300K K0.4cm cm-20~60℃ ℃—D±0.25% (D Refers to the Measured Range)IP68 (Pressure Resistant to 50m)Stainless Steel 316—————<2000ms (Software Delay Protection) ms10.8V~26.4VDC, Reverse Polarity Protection VDC——————Default 5m (Other Lengths Available on Custom Order) m——≤100mA mA2cm±0.5% D (D Refers to the Measured Range)9.7° ±1° °4-Core Cable Outlet / Aviation Connector Outlet250ms / cycle ms/cycle0.4m~50m m—————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————
Sound Velocity and Sound Attenuation Measuring Instrument
Sound Velocity and Sound Attenuation Measuring Instrument

Sound Velocity and Sound Attenuation Meter

——RS-485 (Modbus RTU Protocol) Type-C Interface———————-40~+80℃ ℃———-20~+60℃ ℃————GB/T 15261-2008—————85VAC~305VAC (50Hz/60Hz) VAC———————————————YY/T 0299-2022GB/T 18022-2000Standard 1m (Other cable lengths require customization) m500mA mA1~8 MHz (Default: 3.1MHz) MHz1 Standard Atmosphere standard atmosphereABSBNC RF ConnectorAluminumIP68IP6X——————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————
Portable Ultrasonic Doppler Flowmeter
Portable Ultrasonic Doppler Flowmeter

Portable Ultrasonic Doppler Flow Meter

8.52kg±0.1kg kg—————————-25~80℃ ℃———-5~60℃ (non-freezing conditions) ℃Modbus RTU—IP68——Portable Ultrasonic Doppler Flow Meter——————————————————————Standard 10m (other lengths available upon customization) m————————Type-C≤10NTU cannot be measured NTUWater level, flow velocity, temperature, instantaneous flow, totalized flow30000 records recordsCircular, rectangular, trapezoidal, irregular channels3.5-inch LCD backlit displayPUStandard 2.5m (0.5m*5) m3.6V/5200mAH600mAH (at 25℃ ambient temperature, can operate continuously for 6 hours) mAH304 stainless steelpH value between 6~104-core (single core 0.21m²) shielded cable with built-in air tube, outer diameter 8mmPOM+(ABS+PC)0.1m³~34560000000m³ m³ABS3~5VDC (3.6V lithium battery) VDC0.01℃ ℃1mm/s mm/s1m³/h~720000000m³/h m³/h0.001L L±1%~±3% (measurement accuracy varies with on-site working conditions) %10~24VDC VDC±0.03m/s~5m/s m/s0.001 m³/s m³/s±30mm mmIP653mm mm±(V*%1+0.01)m/s (accuracy verified by the Hydrological Verification Center)0.02~10m m————————————————————————————————————————————————————————————————————————————————————————————
Ultrasonic Underwater Communication Sensor
Ultrasonic Underwater Communication Sensor

Ultrasonic Underwater Communication Sensor

1500g±30g (including 10m cable weight) g—————————————0~+60°C °C——————————————————————180° °————————————————————————————————————————————3s s≤8% (depending on operating environment and sensor angle) %IP68 (withstands water depth up to 100 m)96bps (Maximum) bpsHexadecimal values corresponding to 1-12 ASCII charactersHalf-duplex, RS-485 (Modbus RTU Protocol)-20~+60°C, environment free of corrosive liquids and gasesWater depth greater than 2 m; keep away from motors and variable-frequency equipment100m m12VDC±10% (powered by battery or DC linear power supply); power consumption is 1W in receiving mode and 3.5W in transmitting modeRed — 12V positive; Black — 12V negative; Blue — 485A; Yellow — 485BRed — 12V positive; Black — 12V negative; Blue — 485A; Yellow — 485B; Green and White — relay contacts (contact rating: 1.5A/30VDC)————————————————————————————————————————————————————————————————————————————————
M33 Patch Underwater Obstacle Avoidance Sensor
M33 Patch Underwater Obstacle Avoidance Sensor

M33

78g (2m cable) 85g (2m cable) 85g (2m cable)—RS-485 (Modbus RTU Protocol)—0.05~3m 0.05-8m 0.05~10m m———10.8V~26.4VDC, Reverse Polarity Protection VDC—-20~+60°C °C0.02m±0.5%D (D refers to the measured range)2MHz 1MHz 800kHz0.05m 0.05m 0.05m m-20~+60°C °C—0.25%D (D refers to the measured range)IP68 (pressure resistant to 50m)Aluminum Alloy—————<2000ms (Software Delay Protection) ms—————4-core shielded cable, direct lead-out—Default 2m (other lengths available on request) m——≤100mA mA—2.1°±0.5% 4.6°±0.5% 7.8°±0.4%—100ms/time 115ms/time 115ms/time——————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————
M33 Underwater Obstacle Avoidance Sensor
M33 Underwater Obstacle Avoidance Sensor

M33

118g (2m cable)|113g (2m cable)—RS-485 (Modbus RTU protocol)—0.25~20m|0.1~8m———10.8V~26.4VDC, reverse polarity protection VDC—-20~+60℃ ℃0.02m±0.5%D (D is the measured range)300K|1MHz0.25m|0.1m-20~+60℃ ℃—0.25%D (D is the measured range)IP68 (pressure-resistant to 50m)Aluminum alloy—————≤2000ms (software delay for protection) ms———————Default 2m (other cable lengths require customization) m——≤100mA mA—19.4°±1.9°|4.6°±0.5°Direct cable outlet140ms/cycle|115ms/cycle——————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————
Single/Double Sheet Detection Sensor (Dedicated to Label Measurement)
Single/Double Sheet Detection Sensor (Dedicated to Label Measurement)

Single/Double Sheet Detection Sensor (for Label Measurement)

————Transducer mounting distance: 0.03~0.08 m; ideal value 0.045~0.06 m m≤80mA mAPOM (transducer), ABS (control box)—24 VDC (±10%) VDC—————————————————————————————————————————————————————————————————————————————————————LED display 0: empty / no paper LED display 1: single sheet or no label LED display 2: double sheets or label present1.5m (default) m3 NPN switching outputsThrough-beam3×100mA200kHz±10% kHz5.3mm±0.3mm mmTransducer thread M18*1.52mm±0.03mm mm2m m——————————————————————————————————————————————————————————————————————
Ultrasonic Single-Channel Externally Mounted Liquid Level Switch (New Model)
Ultrasonic Single-Channel Externally Mounted Liquid Level Switch (New Model)

Ultrasonic Single-Channel Externally Mounted Liquid Level Switch (New Model)

——————ABS———-20~+60°C °C—1MHz, 2MHz—-10~+55°C °C—————Ultrasonic Single-Channel Externally Mounted Liquid Level Switch————24VDC (±10%) VDC—≤30mA mA————————————————————————————————————————————————————————————————————————————Relay Alarm IndicatorPower Indicator (Steady On)Optional 2 SPST (Single-Pole Single-Throw) relays; Contact Rating: AC 250V/5A or DC 28V/5A; Normally Open by Default1.5m by Default (Other Lengths Available on Request) mGX16 4-Pin Connector—————————————————————————————————————————————————————————————————
Dedicated Sensor for Cattle Detection in Pastures
Dedicated Sensor for Cattle Detection in Pastures

Dedicated Sensor for Pasture Cattle Detection

<300 g (excluding cable) g0.001m mNPN switching output, normally open (voltage drop: ≤3.5 V)——≤25 mA mA——24 VDC ±10%, reverse polarity protection—-40°C~+80°C °C±0.5% FS or ±0.03m (whichever is greater)40 kHz kHz0.25m m-20°C~+60°C °C—0.25%FS %FSIP68ABS housing————0.25~3m m≤300 ms ms——————————≤100 mA mA—85° °——0.25~3m m————————————————————————————————————————————————————————————————————3% of the set switching distance————————————————————————————————————————————————————————————————
M30 Ultrasonic Distance Measurement Sensor
M30 Ultrasonic Distance Measurement Sensor

M30

<250g (excluding cable) g0.001m m4~20mA analog output (load ≤500R at 24VDC)———————-40~+85°C °C±0.5%FS or ±0.03m (whichever is greater)——-20~+60°C °C—0.25%FS %FS—Housing: 304 stainless steel; Transducer: ABSGB/T 14048.10-2016—0~10V analog output (load ≥1k)NPN switching output, normally open (voltage drop: ≤3.5V)0.2~6m m—24VDC±10%, with reverse polarity protection VDCGreen LED, analog output status indicator: steady on within range, flashes when out of range≤25mA mAYellow LED, switching output indicator: steady on when conducting—M12 8-pin connectorM30*1.5———≤100mA mA————0.2~6m mGB/T 14048.19-2013—2m by default (other lengths available on request) m—————————————————————————————————————————————————————————————————3% of the set switching distance %PNP switching output, normally openStandard RS-485 output (Modbus RTU protocol)≤300ms msIP67————————————————————————————————————————————————————————————
M18 Ultrasonic Distance Measurement Sensor
M18 Ultrasonic Distance Measurement Sensor

M18

<100g (excluding cable) g0.001m m4~20mA Analog Output (Load capacity varies with supply voltage: 10VDC load ≤250R; 28VDC load ≤500R) 0~10V Analog Output (Supply range for this output: 12V~30V, load ≥1k) NPN Switching Output, Normally Open (Voltage drop: ≤3.5V) PNP Switching Output, Normally Open (One of the above 4 options selectable) RS-485 (Modbus RTU Protocol)—0.06~1m m———10V~30VDC, Reverse Polarity Protection VDC—-40~+85℃ ℃±0.5%FS or ±0.03m (whichever is greater)200kHz kHz0~0.06m m-20~+60℃ ℃—0.25%FS %FSIP67Housing: Stainless Steel + High-Transparency PC————0.06~1m m≤300ms ms——≤25mA mA———M18×1.0Default 2m (Other cable lengths require customization) m——≤100mA mA——M12 8-pin Connector——————————————————————————————————————————————————————————————————Switching/Analog Output Range Indicator Light———3% of the set switching distance————Power Indicator LightGB/T 14048.10-2016 GB/T 14048.19-2013——————————————————————————————————————————————————————————
M70 High-Pressure Resistant Distance Measurement Sensor(Titanium Alloy Material)
M70 High-Pressure Resistant Distance Measurement Sensor(Titanium Alloy Material)

M70

——RS-485 (Modbus RTU protocol)———————-20~60°C °C—1MHz MHz—-20~60°C °C—D±0.25% (D refers to the measured range)—Titanium alloy—————<2000ms (software delay for protection) ms10.8V~26.4VDC, reverse polarity protection VDC——————Default 2m (other lengths available upon customization) m——≤100mA mA2cm±0.5% D (D refers to the measured range)4.6°±0.5° °4-core cable outlet / aviation connector outlet115ms / cycle ms0.1m~8m m————————————————————————————————————————————————————————————————————————IP68 (pressure resistant to 2000m)——0.1m m—————————————————————————————————————————————————————————
M30 Wood Panel Bulging Sensor-Non-Corrosion-Resistant Type
M30 Wood Panel Bulging Sensor-Non-Corrosion-Resistant Type

M30

350g~770g (weight varies depending on internal configuration) g——15ms ms—<80mA mA———————————IP65———————DC 18V~30V V——————————————————————————————————————————————————————————————————————3-channel NPN outputThrough-beam; transmission power configurable via 485 bus———————————————————DC 24V power supply positiveRS-485 communication signal AWooden board detected between the through-beam probes, but no bulgeWooden board detected between the through-beam probes, with bulgeUltrasonic transmission power, host computer control signal (floating or high level = high-power transmission, low level = low-power transmission)DC 24V power supply negativeNo object detected; air between the through-beam probesRS-485 communication signal BNickel-plated brass (other materials available upon request)15ms msM30×1.5 threaded connection60~150mm; ideal value: 90~110mm mm<100mA mANo-load power consumption <2W WFull-load power consumption <9.2W W3000mm±300mm (customizable length) mm100mm~1300mm (customizable length) mm500mm~700mm (customizable length) mm5mm±0.03mm mm5mm±0.03mm mm5mm±0.03mm mm————————————————————————————————————
Sewer ultrasonic Doppler flow meter
Sewer ultrasonic Doppler flow meter

Sewer ultrasonic Doppler flow meter

2.5kg (including 20m cable) kg—————————-25~80°C °C———-5~60°C (non-freezing conditions) °C——IP68——Sewer Doppler Flowmeter——————————————————————————————————————————pH value between 6~10 pH—————0.01°C °C1mm/s mm/s————0.03m/s~5m/s, -5m/s~-0.03m/s (customizable ±0.03m/s~±10m/s) m/s———————————4G-CAT.1, NB-IoT——————————————————————————————————————————————————Standard type: 4-core shielded cable, 4.5mm diameter; Enhanced type: 4-core shielded cable with air guide tube, 8mm diameter (default cable length 10 m; other lengths require customization)Supply Range: 5VDC~15VDC VDCThis model uses an external level meter; the level meter type and range are freely selected by the customer1 L/s ~ 99999999 m³/hFlow Velocity, Flow Rate, Water Temperature, Water Depth±3cm cm±(V*1%+0.01)m/s (accuracy verified by the Hydrological Verification Center) m/s20mg/L~20g/L3mm mm±1%~±3% (measurement accuracy varies depending on on-site working environment) %POM+(ABS+PC); Cable Material: PUPC+ABS or 304 Stainless Steel (choose one of the two)0.02~10m m0.08~3m (default: pressure depth measurement) m——————————————————————
Transducer test board
Transducer test board

Transducer test board

———————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————15VDC VDC————————————15KHZ, 21KHZ, 25KHZ, 34KHZ, 40KHZ, 49KHZ, 64KHZ, 80KHZ, 100KHZ, 120KHZ, 150KHZ, 200KHZ, 250KHZ, 300KHZ KHZ1×, 10×, 100×, 1000× ×————————————————————
Ultrasonic noise detection sensor
Ultrasonic noise detection sensor

Ultrasonic noise detection sensor

—10mV mV———————————————IP68———————9VDC~36VDC VDC————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————4-core shielded cableSine Wave (sampled signal output at 10× and 100× amplification)RS485- 5°C ~60°C °C————————————————
Low-power radar manhole level meter
Low-power radar manhole level meter

Low-power radar manhole level meter

—1mm mm———————————————Main Unit Protection Rating: IP68 at 10m water depth, Radar Protection Rating: IP68 at 10m water depth——Low-Power Radar Manhole Level Meter————12VDC VDC——————————±3mm mm———————————————————————≥100AH AH—————————————————————————————————————————————————————————————————————————————————————————————————1 minute-24 hours configurable minParameter setting via mobile phone BluetoothRechargeable lithium battery pack with independent sealed enclosure-40~+85℃ ℃1 minute-24 hours configurable min1 minute-24 hours configurable minN serial ports (Serial Port 1: RS232/RS485 selectable, Serial Port 2: RS485)0%~100%RH %RH-25℃~+55℃ ℃0~20m m——————
M30 Wood Board Bulge Sensor - Non-Corrosion-Resistant Type / Board Defect Detection / Wood Board Hollow Detection
M30 Wood Board Bulge Sensor - Non-Corrosion-Resistant Type / Board Defect Detection / Wood Board Hollow Detection

M30

——————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————
M70 High-Pressure-Resistant Depth Sounder
M70 High-Pressure-Resistant Depth Sounder

M70

——————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————
Sixteen-Beam Underwater Obstacle AvoidanceSensor. Detail Page_01.jpg
Sixteen-Beam Underwater Obstacle AvoidanceSensor. Detail Page_01.jpg

16-Beam Underwater Obstacle Avoidance Sensor (Split Type)

——————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————
IP68 Ultrasonic Water Level Meter (3.6V power supply, ABS material)
IP68 Ultrasonic Water Level Meter (3.6V power supply, ABS material)

IP68

——————————-40℃~+80℃ ℃±0.5%FS %FS——-20℃~+60℃ ℃—————IP68 Ultrasonic Water Level Meter (3.6V)————3.6VDC±0.2V VDC——————————————————————————————————————————————————————————IP68 Rated for 10 m Water Depth——————————————————————————————————————————————————————————————————————NoneRS485 MODBUS-RTU Protocol———————————ABS/PTFE Probe6.3mm Four-Core Shielded Cable mmNPT2"/G2A Thread≤15MA (Continuous Operation) mA≤1 Standard Atmosphere atm0.15-2m, 0.25-5m, 0.3-8m m