跳转到主要内容
logo
👤

Products

128 products

ImageModel / Name
Protection Rating
Operating Temperature
Operating Voltage
Output Type
Blind Zone
Storage Temperature
Transducer Frequency
Detection Range
Weight
Measurement Accuracy
Emission Angle
Startup Delay
Material
Repeatability Accuracy
Output Connection Method
Installation Method
No-load Current
Output Cable Length
Resolution
Housing Material
Accuracy
Fastest Response Time (Active Upload)
Ambient Temperature
Output Signal
Sixteen-beam Ultrasonic Distance Measurement Obstacle Avoidance Sensor (Underwater)
Sixteen-beam Ultrasonic Distance Measurement Obstacle Avoidance Sensor (Underwater)

16-beam ultrasonic distance measurement obstacle avoidance sensor (in water)

Probe IP68, Main Unit IP54 (main unit must be placed in a sealed enclosure)-20℃~ +60 ℃——0.15 m————0.02m + 0.5% D (D refers to the measured range)—————Split Installation (probe separated from circuit board)——0.001 m—————
16-Beam Ultrasonic Distance Measurement Obstacle Avoidance Sensor (in Air)
16-Beam Ultrasonic Distance Measurement Obstacle Avoidance Sensor (in Air)——————————————————0.001 m—————
Handheld Depth Sounder S20 Pro+M33 Patch Underwater Obstacle Avoidance Sensor
Handheld Depth Sounder S20 Pro+M33 Patch Underwater Obstacle Avoidance Sensor—-20°C~+60 °C—RS-485 (Modbus RTU Protocol)—-20°C~+60 °C2 MHz——0.02m ±0.5% D (D refers to the measured range) m—≤2000 ms—0.25% D (D refers to the measured range)4-Core Shielded Cable with Direct Outlet——Default 2m (Customizable) m——————
Ultrasonic Crack Detection Sensor
Ultrasonic Crack Detection Sensor—-10~60 ℃24VDC(±10%) VDC——-20~60 ℃—0.01~0.5 m————————<20 mA——POM (transducer), ABS (control box)———RS-485
M45 Leak Detection Hydrophone
M45 Leak Detection Hydrophone

M45

————————≤800g, Including 2m Attached Cable g———304 Stainless Steel Housing——Magnetic Mount; Clamp Fixing————————
3.6V Micro-Power IP68 Ultrasonic Water Level Meter (NPT 2" Thread, ABS Material, Bluetooth Communication)
3.6V Micro-Power IP68 Ultrasonic Water Level Meter (NPT 2" Thread, ABS Material, Bluetooth Communication)

3.6V

IP68-20~+60 ℃DC 3.6 V——-40~+80 ℃——≤1000 g———————————±0.5 %FS———
Ultrasonic dual-channel clamp-on liquid level switch
Ultrasonic dual-channel clamp-on liquid level switch—-10~55 °C24VDC(±10%) VDC——-20~60 °C—————————Magnetic suction / clamp / adhesive≤30 mA——ABS————
Dual-channel split-type insertion ultrasonic liquid level switch
Dual-channel split-type insertion ultrasonic liquid level switchSensor IP68, Controller IP65Sensor -10~80°C, Controller -20~60 °C———-20~60 °C——————————13 mA———————
Four-beam underwater obstacle avoidance sensor (split type)
Four-beam underwater obstacle avoidance sensor (split type)Probe IP68 (Pressure Resistant 150m)-20~+60 °C10.8VDC~26.4VDC, Reverse Polarity Protection VDCStandard RS-485 (Modbus RTU Protocol), TTL Output Optional0.15 m-20~+60 °C—3 m—0.01m±0.5%D (D Refers to the Measured Range)—≤1000 ms—0.25%D (D Refers to the Measured Range)——————————
M26 Leak Detection Hydrophone
M26 Leak Detection Hydrophone

M26

————————≤350 g, including 2 m additional cable g———304 stainless steel housing———————————
Road waterlogging sensor (split type) / road waterlogging, underpass waterlogging monitoring / road surface water level monitoring
Road waterlogging sensor (split type) / road waterlogging, underpass waterlogging monitoring / road surface water level monitoring

Road waterlogging sensor (split type) / road water accumulation, underpass water accumulation monitoring / road water level monitoring

—————————±0.5% (of Max. Range) %————————————-20°C~60 °C—
Integrated Ultrasonic Level Meter
Integrated Ultrasonic Level MeterIP65————————0.5%~1.0 %————————1mm or 0.1% (whichever is greater) mm———Display instrument -20~+60°C, Probe -20~+80 °C—
Ultrasonic dual-probe ranging sensor
Ultrasonic dual-probe ranging sensor

Ultrasonic dual-probe distance measurement sensor

IP68-20~+60 °C10~30VDC, Reverse Polarity Protection VDCRS-485 (Modbus RTU Protocol)0~0.05 m-40~+80 °C100 kHz0.05~2 m<300g (excluding cable) g±0.5%FS or ±0.03m (whichever is greater)11.7° ±5% °—ABS0.25 %FS————0.0005 m—————
M36 Underwater Obstacle Avoidance Sensor (ABS material, aviation plug version)
M36 Underwater Obstacle Avoidance Sensor (ABS material, aviation plug version)

M36

IP68 (pressure resistance 150m)-20~60 °C10.8V~26.4VDC, reverse polarity protection VRS-485 (Modbus RTU protocol)0.3m / 0.4m / 0.1m / 0.05 m-20~60 °C300K / 300K / 1MHz / 2MHz0.3~20m / 0.4~50m / 0.1~8m / 0.05~3 m151g (2m cable direct outlet) / 114g (aviation plug version, net weight) / 94g (aviation plug version, net weight) / 90g (aviation plug version, net weight) g—19.4°±1.9° / 10°±1° / 4.6°±0.5° / 2.1°±0.5 °<2000ms (software delay for protection) msABS±0.25 %4-core cable outlet / aviation plug outlet——Default 2m (other cable lengths require customization) m——0.02m±0.5%D (D refers to the measured depth)140ms/time / 300ms/time / 115ms/time / 110ms/time ms——
PCM60 Ultrasonic Ranging Sensor
PCM60 Ultrasonic Ranging Sensor

PCM60

IP68-20°C~+60 °C24V±10% V—0.2 m-40°C~+80 °C64kHz±5% kHz0.2~3.5 m235 g±0.5%FS or ±0.03m (whichever is greater)———0.25 %FS——≤25 mA—0.001 mABS————
Ultrasonic Dual-Channel Distance Measurement Sensor
Ultrasonic Dual-Channel Distance Measurement SensorTransducer IP68, Main Unit Housing IP67-20~+60 °C21.6VDC~26.4VDC, Reverse Polarity Protection VDC2-channel NPN switch output, normally open (voltage drop ≤2.5V)0~0.05m (Range: 1.5m) m-40~+80 °C100 kHz0.15~1.5 mApprox. 500 g——≤300 msTransducer Made of PVDF, Housing Made of ABS————Default 1m (Other Cable Lengths Require Customization) m——————
M45 Underwater Obstacle Avoidance Sensor
M45 Underwater Obstacle Avoidance Sensor

M45

————————————————————2cm±0.5% D (D refers to the measured range) cm/%———
M50 Underwater Obstacle Avoidance Sensor (Hydrological Customization)
M50 Underwater Obstacle Avoidance Sensor (Hydrological Customization)

M50

IP68 (Pressure Resistance 50m)-20~60 °C10.8V~26.4VDC, Reverse Polarity Protection VDCRS-485 (Modbus RTU Protocol)0.4 cm-20~60 °C300K0.4m~50 m——9.7°±1 °<2000ms (Software Delay for Protection) msStainless Steel 316D±0.25% (D Refers to the Measured Range) %4-Core Cable Outlet / Aviation Connector Outlet——Default 5m (Other Cable Lengths Require Customization) m——2cm±0.5% D (D Refers to the Measured Range) cm250 ms/次——
Sound Velocity and Sound Attenuation Measuring Instrument
Sound Velocity and Sound Attenuation Measuring Instrument

Sound Velocity and Sound Attenuation Meter

—-20~+60 °C85VAC~305VAC(50Hz/60Hz) VAC——-40~+80 °C——————————————————
Portable Ultrasonic Doppler Flowmeter
Portable Ultrasonic Doppler Flowmeter

Portable Ultrasonic Doppler Flow Meter

————————8.52kg±0.1kg———————————————
Ultrasonic Underwater Communication Sensor
Ultrasonic Underwater Communication SensorIP68 (can withstand water depth up to 100 m)———————1500g±30g (including the weight of the 10m cable) g———————————————
M33 Patch Underwater Obstacle Avoidance Sensor
M33 Patch Underwater Obstacle Avoidance Sensor

M33

IP68 (pressure resistant to 50m)-20~+60 °C10.8V~26.4VDC, reverse polarity protection VDCRS-485 (Modbus RTU protocol)0.05 m-20~+60 °C2MHz / 1MHz / 800kHz0.05~3m / 0.05-8m / 0.05~10 m78g (2m cable) / 85g (2m cable) / 85g (2m cable) g0.02m±0.5%D (D refers to the measured range) m2.1°±0.5% / 4.6°±0.5% / 7.8°±0.4% °<2000ms (software delay for protection) msAluminum alloy0.25%D (D refers to the measured range) %D4-core shielded cable, direct outlet——Default 2m (other cable lengths require customization) m———100ms/time / 115ms/time / 115 ms/次——
M33 Underwater Obstacle Avoidance Sensor
M33 Underwater Obstacle Avoidance Sensor

M33

IP68 (pressure resistant to 50m)-20~+60 °C10.8V~26.4VDC, Reverse Polarity Protection VDCRS-485 (Modbus RTU Protocol)0.25m | 0.1 m-20~+60 °C300K | 1MHz0.25~20m | 0.1~8 m118g (2m cable) | 113g (2m cable) g0.02m ±0.5%D (D is the measured range)19.4°±1.9° | 4.6°±0.5 °≤2000ms (software delay for protection) msAluminum Alloy0.25%D (D is the measured range) %Direct Cable Outlet——Default 2m (other lengths require customization) m——————
Single/Double Sheet Detection Sensor (Dedicated to Label Measurement)
Single/Double Sheet Detection Sensor (Dedicated to Label Measurement)

Single/Double Sheet Detection Sensor (for Label Measurement)

———————Transducer mounting distance: 0.03~0.08 m; ideal value 0.045~0.06 m————————≤80 mA——POM (transducer), ABS (control box)———3 NPN switch outputs