Correct Range Settings for Modifying the Span of Dayu Electronics Ultrasonic Level Meters
During on-site commissioning of Dayu Electronics ultrasonic level meters, you may sometimes find that a modified span cannot be saved. This is usually not an instrument fault, but rather the set span exceeds the meter's rated measuring range.

Dayu Electronics ultrasonic level meters have a fixed maximum span determined at the factory. This upper limit is jointly determined by the transducer, circuitry, and calibration. Users can freely adjust within the range, but cannot exceed it. For example, if you ordered a 10-meter span Dayu Electronics ultrasonic level meter, the maximum settable span is 10.00 meters. If you attempt to set the span beyond 10.00 meters, the meter will refuse to save because the hardware cannot support a larger measuring range.

Conversely, as long as the set value does not exceed 10.00 meters—for example, setting it to 8 meters, 9 meters, or 10.00 meters—it can be saved and take effect normally. In other words, when modifying the span, first check whether the target value falls within the meter's allowable span range. Within the range, saving is no problem; beyond the range, save failure is the meter's normal protection logic, preventing users from setting an actually unachievable span that would lead to unreliable subsequent measurement data.

Therefore, when you cannot save the span, the first step is to verify the current meter's rated span. You can check the meter's nameplate, factory label, or manual to confirm the ordered span. The second step is to compare the value you need to set with the rated span. If the target value is greater than the rated span, you must reduce it to within the rated span and save again. If the site genuinely requires a larger measuring range, this cannot be achieved by modifying parameters; you should contact Dayu Electronics to replace it with an ultrasonic level meter with a larger span, or have technical personnel evaluate whether other adaptation solutions are available.

The core of Dayu Electronics ultrasonic level meter's span setting logic is "adjustable within the range, not settable beyond the range." Understanding this point can help you avoid detours during commissioning. When encountering save failure, there is no need to try repeatedly; first confirm whether the target span exceeds the limit, then modify within the allowable range, and it can usually be saved smoothly. If you still have questions, please contact the Dayu Electronics technical team; we will provide clear guidance based on specific models and site conditions.