Dayu Electronics Doppler Flow Meter Minimum Water Level Requirements
Dayu Electronics Doppler flow meters have different minimum water level requirements depending on probe structure and emission angle. Standard dual-probe circular models require approximately 95mm, standard single-probe angled models require approximately 260mm, and 0° parallel-emission low-water single-probe models require approximately 60mm. Selection should prioritize matching the model to on-site minimum water level, channel width, and installation position.

Circular Dual-Probe Doppler Flow Meter: Minimum Water Level ~95mm
With a diameter of about 75mm, the circular dual-probe Doppler flow meter requires sufficient water coverage above the sensor top after installation, with a minimum water level requirement of approximately 75mm+20mm=95mm. This model suits channels or pipes with relatively stable water levels and ample installation space.

Single-Probe Angled Doppler Flow Meter: Minimum Water Level ~260mm
The small single-probe Doppler flow meter uses approximately 34° angled emission, with sound waves entering the water obliquely upward, requiring higher water levels to ensure effective beam coverage of the measurement area. The minimum water level requirement is approximately 260mm. This model is better suited for deeper water and stable flow distribution conditions.

0° Parallel-Emission Low-Water Doppler Flow Meter: Minimum Water Level ~60mm
The low-water single-probe Doppler flow meter uses 0° parallel emission, with sound waves propagating horizontally along the flow direction, minimizing interference from water surface and bottom reflections. The minimum working water level is approximately 60mm. This model suits inspection wells, box culverts, shallow channels, and partially full pipe outlets.

Actual Selection Requires Confirmation Based on Channel and Installation Conditions
Minimum water level values may vary slightly with sensor body height, mounting bracket height, and channel bottom sedimentation. If the on-site minimum water level approaches critical values, it is recommended to provide channel cross-section dimensions, minimum water level, flow velocity range, and installation method for Dayu Electronics technical team to confirm the specific model and installation height.