Dayu Electronics 500kHz-1.2MHz Broadband Transducer Dual-Model Solution
The 500kHz-1.2MHz frequency range spans more than two octaves, making it difficult for a single transducer to maintain ±3dB frequency response flatness and 140dB transmitting voltage response across the entire band. We recommend using two broadband transducers to cover the band in segments, with one covering 500kHz-800kHz and the other covering 800kHz-1.2MHz, achieving full-band coverage through switching or combined use.

Low-Frequency Band: KDYW-600-01E Covers 500kHz-800kHz
The KDYW-600-01E has a -3dB bandwidth greater than 20%, with an effective transmitting frequency range of 500kHz-800kHz, covering the low-frequency portion of the target band. This model is suitable for low-frequency stepped frequency sweep tasks, and the frequency response curve remains relatively stable within this range during point-by-point testing at 10kHz steps.

High-Frequency Band: KDYW-1M-01TA Covers 800kHz-1.2MHz
The KDYW-1M-01TA has a -3dB bandwidth of approximately ±20%, with an effective transmitting frequency range of 800kHz-1.2MHz, covering the high-frequency portion of the target band. When combined with the low-frequency transducer, the two transducers together cover the full 500kHz-1.2MHz band.
±3dB Frequency Response Flatness Requires Actual Measurement Verification
±3dB is a stringent frequency response requirement, and actual flatness is closely related to driving voltage, load impedance, test distance, and test method. Accurate evaluation of transducer bandwidth requires acoustic measurement using the pulse-echo method or hydrophone method. We recommend point-by-point frequency sweeping within the target band and plotting the frequency response curve to confirm whether the ±3dB requirement is met.

140dB Transmitting Voltage Response Requires Evaluation Based on Driving Conditions
Transmitting voltage response is directly related to driving voltage, transducer impedance, and frequency point. Impedance varies significantly with frequency within the 500kHz-1.2MHz band, so the actual response value must be calculated based on specific driving voltage and impedance curves. If a single transducer cannot achieve 140dB at certain frequency points, compensation can be made by increasing the driving voltage or optimizing the matching circuit.

Complete Test Conditions Recommended for Precise Model Selection
We recommend that customers provide information such as the specific application of stepped frequency sweep, driving voltage range, load impedance requirements, test distance, and medium conditions. The Dayu Electronics technical team can confirm whether the KDYW-600-01E and KDYW-1M-01TA meet the ±3dB and 140dB specifications based on actual operating conditions, or recommend a more suitable custom solution.