Dayu Electronics DN80-DN100 Pipe Flow Measurement Selection Guide
DN80-DN100 pipes are not recommended for ultrasonic Doppler flow velocity meters. Depending on whether the pipe is full, select either a clamp-on ultrasonic flowmeter or a dual-probe ultrasonic open channel flowmeter.

Doppler velocity meters are unsuitable for DN80-DN100 small-diameter pipes
Ultrasonic Doppler flow velocity meters are better suited for larger diameter pipes or open channel applications, typically requiring pipe diameters greater than DN200, and the minimum water level must meet sensor submersion requirements. DN80-DN100 pipes have limited internal space, making sensor installation difficult, and the flow velocity distribution is significantly affected by the pipe wall, making it impossible to accurately convert flow rates using Doppler velocity measurement.

Clamp-on ultrasonic flowmeters recommended for full pipe conditions
If the pipe contains ordinary water or river water and is in a full pipe state, a clamp-on ultrasonic flowmeter is recommended. This solution is suitable for DN15-DN6000 pipe diameters, with DN80-DN100 falling within the small sensor application range. The sensors clamp onto the outer pipe wall without pipe cutting, offering convenient installation. Note that the pipe material should be uniform and dense such as carbon steel, stainless steel, or PVC, and the installation location must meet straight pipe section requirements of 10D upstream and 5D downstream.

Dual-probe ultrasonic open channel flowmeters recommended for partially filled pipe conditions
If the pipe has consistently low water levels and is in a partially filled state, it is recommended to install an open channel or weir flume at the pipe outlet and use a dual-probe ultrasonic open channel flowmeter for measurement. This solution measures liquid level combined with weir flume models to calculate flow rates, with a measurement blind zone of only 0.08 meters, making it particularly suitable for low water level scenarios.
Provide operating condition information for accurate selection
Customers are advised to provide information such as pipe material, whether the pipe is full, minimum water level height, and straight pipe section conditions at the installation location. The Dayu Electronics technical team will assist in confirming specific models and installation solutions.