Dayu Electronics 40m Split-Type Ultrasonic Level Meter for Bridge Clearance Measurement
Dayu Electronics offers a 40m range split-type ultrasonic level meter, suitable for measuring navigable water clearance (air draft) on bridges. The split design mounts the sensor on the bridge deck or underside bracket, with the display unit installed in an accessible location for easy on-site installation and maintenance.

40m Range as Standard Option for Split-Type Units
Dayu Electronics split-type ultrasonic level meters cover standard ranges from 5m to 30m, with special options of 30m, 40m, and 50m. The sensor emits ultrasonic waves vertically downward to measure the distance from the probe to the water surface (clearance value). The host can display clearance or convert it to navigable height via parameter settings.

Bridge Installation Requires Blind Zone and Range Margin Consideration
Ultrasonic level meters have a measurement blind zone where echoes cannot be accurately identified near the sensor emission surface. During selection, confirm that the distance from probe to water surface at maximum water level exceeds the blind zone, while at minimum water level it remains within range. If bridge clearance varies significantly, reserve margin beyond 40m to avoid exceeding range at extreme low water levels.

Outdoor Bridge Environment Requires Protection and Anti-Interference
Bridge sites typically involve wind, waves, rain, fog, temperature fluctuations, and vibration. The split-type sensor achieves IP68 protection, while the host is generally IP65. Install away from bridge beams, railings, and cables; ensure no obstacles in the acoustic beam path below the probe to avoid false echoes. Outdoor installation should include sun and rain shields to extend service life.

Signal Output and Remote Transmission Configurable as Needed
The split-type ultrasonic level meter supports 4-20mA analog output and RS485 communication, connectable to bridge monitoring systems, PLCs, or host computers. If the host is far from the sensor, confirm probe cable length; split-type probe cables can reach up to 100m.
Customers should provide bridge probe installation height, maximum and minimum water levels, navigable clearance requirements, host installation location, and signal access method. Dayu Electronics technical team will confirm whether the 40m range meets site blind zone and range margin requirements, and recommend suitable sensor frequencies and mounting bracket solutions.