Dayu Electronics Split-Type Ten-Beam Underwater Obstacle Avoidance Sensor 150m Communication Cable Solution
Dayu Electronicssplit-type ten-beam underwater obstacle avoidance sensoruses RS485 output, and data can be transmitted normally over a 150-meter wiring distance from the sensor to the display. However, cable selection and wiring methods must meet RS485 communication specifications and cannot be simply judged based on "no interference + 0.5mm² shielded wire".

Cable Specifications Must Meet RS485 Communication Standards
The 150-meter transmission distance has exceeded the recommended applicable range of 0.5mm² wire diameter. According to RS485 communication cable selection specifications, for distances over 100 meters, it is recommended to use dedicated shielded twisted-pair cables with 0.75mm² (18AWG) or thicker wire diameter, with a characteristic impedance of 120Ω. It is recommended to select RS485 dedicated cables with aluminum foil + braided copper mesh double shielding structure, rather than ordinary RVVP or power cable substitutes.

Marine Conditions Require Focus on Electromagnetic Interference Protection
Power systems, motors, frequency converters and other equipment on ships generate strong electromagnetic interference, and the premise of "no electromagnetic interference" is difficult to meet in actual working conditions. It is recommended to use double-shielded twisted-pair cables, and route communication cables separately from power cables, maintaining at least 20cm spacing to avoid parallel installation.
Shielding Layer Grounding and Terminal Resistors Must Be Correctly Configured
The shielding layer should use single-end grounding, usually grounded at the display/host end, to avoid ground loop interference caused by multi-point grounding. Although 150-meter distance usually does not require 120Ω terminal resistors (generally only considered for distances over 300 meters), if the communication baud rate is high or on-site interference is severe, terminal resistors can be connected in parallel at the end of the bus to eliminate signal reflection.

Recommended to Have Dayu Electronics Technical Team Confirm Cable Solution
Different sensor models have differences in baud rate, drive capability and anti-interference design. It is recommended to provide specific sensor model, communication baud rate, ship power equipment layout and other information, and Dayu Electronics will assist in confirming cable specifications, grounding methods and whether signal repeaters need to be installed to ensure stable and reliable 150-meter communication.