Ultrasonic sensor
32 products
| Image | Model / Name | Protection Rating | Operating Temperature | Operating Voltage | No-load Current | Output Type | Storage Temperature | Detection Range | Resolution | Measurement Accuracy | Blind Zone |
|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | Ultrasonic Sound Velocity Sensor Ultrasonic Sound Velocity Meter Sensor | — | — | — | — | — | — | — | — | — | — |
![]() | Transducer Test Board | — | — | — | — | — | — | — | — | — | — |
![]() | M36 Patch-Type Ultrasonic Counting Sensor M36 patch ultrasonic counting sensor | IP68 | -20℃~+60 ℃ | DC 10.8 V~26.4 V, Reverse Polarity Protection V | — | Standard RS-485 (Modbus RTU Protocol) | -20℃~+60 ℃ | — | — | — | 0.03 m |
![]() | Ultrasonic Dual-Probe Distance Measuring Sensor (Benchmark) Ultrasonic dual-probe ranging sensor (benchmark) | IP68 | -20℃~+60 ℃ | DC 24 V ±10%, Reverse Polarity Protection V | — | Standard RS-485 (Modbus RTU Protocol) | -40℃~+80 ℃ | — | — | — | ≤0.05 m |
![]() | Ultrasonic Concentration Sensor | — | — | — | — | — | — | — | — | — | — |
![]() | M40 Benchmark Dual-Probe Distance Sensor M40 Benchmark Dual-Probe Distance Measurement Sensor | IP68 (150 m waterproof) | -20°C~+60 °C | DC 24 V ±10%, reverse polarity protection V | — | Standard RS-485 (Modbus RTU protocol) | -40°C~+80 °C | 0.05~1 m | — | — | ≤0.05 m |
![]() | Ice Thickness Gauge | IP68 | — | — | — | — | — | — | — | — | — |
![]() | Ultrasonic Insertion-Type Liquid Level Switch | — | — | — | — | — | — | — | — | — | — |
![]() | Ultrasonic Tree Measurement Sensor (Stainless Steel Probe Version) | — | — | — | — | — | — | — | — | — | — |
![]() | NMM60 Ultrasonic Distance Measurement Sensor NMM60 | IP67 | -20~60 °C | 10~30VDC, Reverse Polarity Protection | ≤25 mA | RS-485 (Modbus RTU Protocol) | -40~80 °C | 200~3000 mm | — | — | 0~200 mm |
![]() | Ultrasonic Surface Flatness Detection Sensor | — | -10~+60 ℃ | 24VDC(±10%) VDC | — | — | -20~+60 ℃ | Rubber, paper, metal, plastic, etc. | — | — | — |
![]() | Non-metal Detector | — | — | — | — | — | — | — | — | — | — |
![]() | Ten-beam Ultrasonic Distance Measurement Obstacle Avoidance Sensor (in air) 10-beam ultrasonic distance measurement obstacle avoidance sensor (in air) | Probe IP66, main unit IP54 | -20℃~+60 ℃ | — | — | — | — | 2.5 m (in air) m | 0.001 m | 0.03m±0.5% FS m | 0.15 m |
![]() | 16-Beam Ultrasonic Distance Measurement Obstacle Avoidance Sensor (in Air) | — | — | — | — | — | — | — | 0.001 m | — | — |
![]() | Ultrasonic Crack Detection Sensor | — | -10~60 ℃ | 24VDC(±10%) VDC | <20 mA | — | -20~60 ℃ | 0.01~0.5 m | — | — | — |
![]() | Ultrasonic dual-channel clamp-on liquid level switch | — | -10~55 °C | 24VDC(±10%) VDC | ≤30 mA | — | -20~60 °C | — | — | — | — |
![]() | Dual-channel split-type insertion ultrasonic liquid level switch | Sensor IP68, Controller IP65 | Sensor -10~80°C, Controller -20~60 °C | — | 13 mA | — | -20~60 °C | — | — | — | — |
![]() | Road waterlogging sensor (split type) / road waterlogging, underpass waterlogging monitoring / road surface water level monitoring Road waterlogging sensor (split type) / road water accumulation, underpass water accumulation monitoring / road water level monitoring | — | — | — | — | — | — | — | — | ±0.5% (of Max. Range) % | — |
![]() | Ultrasonic dual-probe ranging sensor Ultrasonic dual-probe distance measurement sensor | IP68 | -20~+60 °C | 10~30VDC, Reverse Polarity Protection VDC | — | RS-485 (Modbus RTU Protocol) | -40~+80 °C | 0.05~2 m | 0.0005 m | ±0.5%FS or ±0.03m (whichever is greater) | 0~0.05 m |
![]() | PCM60 Ultrasonic Ranging Sensor PCM60 | IP68 | -20°C~+60 °C | 24V±10% V | ≤25 mA | — | -40°C~+80 °C | 0.2~3.5 m | 0.001 m | ±0.5%FS or ±0.03m (whichever is greater) | 0.2 m |
![]() | Ultrasonic Dual-Channel Distance Measurement Sensor | Transducer IP68, Main Unit Housing IP67 | -20~+60 °C | 21.6VDC~26.4VDC, Reverse Polarity Protection VDC | — | 2-channel NPN switch output, normally open (voltage drop ≤2.5V) | -40~+80 °C | 0.15~1.5 m | — | — | 0~0.05m (Range: 1.5m) m |
![]() | Sound Velocity and Sound Attenuation Measuring Instrument Sound Velocity and Sound Attenuation Meter | — | -20~+60 °C | 85VAC~305VAC(50Hz/60Hz) VAC | — | — | -40~+80 °C | — | — | — | — |
![]() | Single/Double Sheet Detection Sensor (Dedicated to Label Measurement) Single/Double Sheet Detection Sensor (for Label Measurement) | — | — | — | ≤80 mA | — | — | Transducer mounting distance: 0.03~0.08 m; ideal value 0.045~0.06 m | — | — | — |
![]() | Ultrasonic Single-Channel Externally Mounted Liquid Level Switch (New Model) | — | -10~+55°C | 24VDC(±10%) | ≤30mA | — | -20~+60°C | — | — | — | — |