Model: Split-type ultrasonic anti-corrosion liquid level gauge | Ultrasonic material level meter.
💬 Online 9:00-18:00 (Mon-Fri) · 📋 Reply within 24h
1. Product Introduction
Ultrasonic level meter (ultrasonic material level meter measures material level, Ultrasonic Level Meter measures liquid level) is a non-contact, high-reliability, cost-effective level measuring instrument that is easy to install and maintain. It can meet most level measurement requirements without contacting the medium. It is a new generation of ultrasonic level meter developed by our company through years of effort and with fully independent intellectual property rights.

2. Simple Debugging
Since the on-site installation environment of the instrument varies, the ultrasonic level meter must know the basic conditions of the required measurement before operation, such as measuring range, zero point, full scale, and site working conditions. Therefore, the instrument must be configured before measurement. For details, please refer to the “Ultrasonic Level Meter Menu Simple Setup Operation Instructions” on the first page.
Others: Please do not modify these three items: probe selection, parameter calibration, and algorithm selection.
Ultrasonic level meter: under normal conditions, after installing the device according to the installation requirements in the manual, set the following parameters and the device will operate normally.
There are three keys on the panel. The instrument can be adjusted using these three keys. After adjustment, the measured value is displayed on the LCD screen.

Functions: 1. Enter menu item, 2. Exit current menu item, 3. Confirm parameter changes.

Functions: 1. Move the cursor, 2. Modify parameters, 3. Select menu.
3. Main Technical Specifications
Function | Integrated type | Split type |
Measuring range | 5 m, 10 m, 15 m, 20 m 30 m, 40 m, 50 m, 60 m | 5 m, 10 m, 15 m, 20 m, 30 m, 40 m, 50 m, 60 m |
Measuring accuracy | 0.5%-1.0% | 0.5%-1.0% |
Resolution | 3mm or 0.1% (whichever is greater) | 3mm or 0.1% (whichever is greater) |
Display | Chinese LCD display | Chinese LCD display |
Analog output | 4-wire 4~20mA/510Ω load 2-wire 4~20mA/250Ω load | 4~20mA/510Ω load |
Relay | Optional 2 AC 250V/8A or DC 30V/5A, status programmable | (Optional) 2 or 4 AC 250V/8A or DC 30V/5A, status programmable |
power supply | Standard configuration: 24VDC Optional 220V AC +15% 50Hz Optional 12V DC or battery power supply | Standard 220V AC +15% 50Hz Optional 24V DC 120mA Custom 12V DC or battery power supply |
Ambient temperature | Display instrument: -20~+60℃ Probe: -20~+80℃ | Display instrument: -20~+60℃ Probe: -20~+80℃ |
Communication | Optional 485 or 232 communication | Optional 485 or 232 communication |
protection rating | Display instrument IP66, probe IP68 | Display instrument IP65, probe IP68 |
Transducer cable | None | Up to 100 m, standard 10 m |
Transducer installation | Based on measuring range and transducer selection | Based on measuring range and transducer selection |
Product power consumption | Split type powered by 24V supply: power consumption is 100mA without relay, 150mA with 2-channel relay, 200mA with 4-channel relay. Specific power is as follows: Without relay: 24 × 100mA = 2.4W; 2-channel relay: 24 × 150mA = 3.6W; 4-channel relay: 24 × 200mA = 4.8W; |
Product power consumption | Integrated four-wire type powered by 24V supply: power consumption is 80mA without relay, 150mA with 2-channel relay. Specific power is as follows: Without relay: 24 × 80mA = 1.92W; 2-channel relay: 24 × 150mA = 3.6W; |
Product power consumption | Integrated two-wire type powered by 24V supply, cannot be equipped with a relay, power consumption is 20mA. Power: 24 × 20mA = 0.48W; |
4. Installation Guide
Level meter installation dimensions: split-type ultrasonic level meter standard type, width × height × thickness = 200 × 210 × 90 mm:


Actual Photo Structure Diagram
Send us your working conditions — engineers reply with selection advice and pricing within 24 hours.