| Image | Model / Name | Protection Rating | Operating Temperature | Operating Voltage | Output Type | Blind Zone | Storage Temperature | Transducer Frequency | Detection Range | Weight | Measurement Accuracy | Emission Angle | Startup Delay | Material | Repeatability Accuracy | Output Connection Method | Output Cable Length | Resolution | Accuracy | Fastest Response Time (Active Upload) | Measuring Range | Ambient Temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | Split-Type Ultrasonic Sludge Level Meter (Probe DYW-200-50KA, ABS Material) | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 5mm or 0.5% (whichever is greater) mm | — | — | — | — |
![]() | Sewer Ultrasonic Doppler Flow Meter (Stainless Steel Housing) Sewer ultrasonic Doppler flowmeter (stainless steel housing) | IP68 (No Water Ingress When Immersed at 10 m Depth) | -20°C~+60 °C | DC 12 V ±10% V | — | — | -40°C~+80 °C | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
![]() | Compact Ultrasonic Doppler Flow Meter (ABS Material, 34° Beam Angle) Compact Ultrasonic Doppler Flow Meter (ABS material, 34° emission angle) | — | -5 to 60°C (non-freezing condition) °C | 12V / 24 V | — | — | -25~80 °C | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
![]() | Split-type Ultrasonic Sludge Level Meter (Probe DYW-500-03A, ABS Material) | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 5mm or 0.5% (whichever is greater) | — | — | — | — |
![]() | Handheld Depth Sounder S20 Pro+M80 Underwater Obstacle Avoidance Sensor (Stainless Steel Housing) Handheld Depth Sounder S20 Pro + M80 Underwater Obstacle Avoidance Sensor (Stainless Steel Housing) | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
![]() | Handheld Depth Sounder S20 Pro+M50 Underwater Obstacle Avoidance Sensor (Stainless Steel Housing) Handheld Depth Sounder S20 Pro + M50 Underwater Obstacle Avoidance Sensor (Stainless Steel Housing) | — | -20℃~+60 ℃ | DC 10~26.4 V | RS-485 (Modbus RTU Protocol) | 0.4 m | -20℃~+60 ℃ | 200 kHz (Large Range) kHz | 0.4~200 m | 463 g | 0.02 m ±0.5% D (D refers to the measured range) m | 11.8°±1.2% ° | ≤2000 ms | — | 0.25% D (D refers to the measured range) %D | 4-Core Cable / Aviation Plug Cable | Default 5 m (Other Lengths Require Customization) m | — | — | 50–65535 ms/time (Adjustable) ms/次 | — | — |
![]() | Split-type Ultrasonic Open-channel Flow Meter (G2 Thread, ABS Material) Split-type Ultrasonic Open Channel Flow Meter (G2 thread, ABS material) | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 3 mm or 0.1% (whichever is greater) | — | — | — | — |
![]() | Split-type ultrasonic level difference meter (G2 thread, PTFE material) | Display instrument: IP65, transducer: IP68 | — | — | — | — | — | — | — | — | 0.5%~1 % | — | — | — | — | — | — | 3mm or 0.1% (whichever is greater) | — | — | — | Display instrument: -20~+60℃; transducer: -40~+80℃ ℃ |
![]() | M32 Hydrophone | — | — | — | — | — | — | — | — | ≤220g Excluding Cable g | — | — | — | 304 Stainless Steel Housing | — | — | — | — | — | — | — | — |
![]() | Split-Type Ultrasonic Level Difference Meter (G2 Thread, PVDF Material) | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 3 mm or 0.1% (whichever is greater) | — | — | — | — |
![]() | 3.6V micro-power IP68 ultrasonic water level meter (NPT 2" thread, PTFE material, Bluetooth communication) | IP68 | -20~+60 ℃ | DC 3.6V | — | — | -40~+80 ℃ | — | — | ≤1000 g | — | — | — | — | — | — | — | — | ±0.5%FS | — | — | — |
![]() | M50 Underwater Obstacle Avoidance Sensor (ABS Housing, Aviation Plug Version) | IP68 (pressure resistant 150m) | -20~60 ℃ | 10.8V~26.4VDC, reverse polarity protection VDC | RS-485 (Modbus RTU protocol) | 0.5m | 0.7m | 0.4m | 0.5 m | -20~60 ℃ | 300K | 200K | 200K (large range) | 88K kHz | 0.5~50m | 0.7~100m | 0.4~200m | 0.5~100 m | 425g (5m cable) | 463g (5m cable) | 463g (5m cable) | 1090g (5m aviation plug cable) g | — | 9.7°±1% | 11.8°±1.2% | 11.8°±1.2% | 27.7°±10% ° | <2000ms (software delay for protection) ms | ABS | D±0.25% (D refers to the measured range) % | 4-core cable outlet / aviation plug outlet | Default 5m (other cable lengths require customization) m | — | 0.02m±0.5%D (D refers to the measured range) | 250ms/time | 290ms/time | 50~65535ms/time (adjustable) | 50~65535ms/time (adjustable) ms/次 | — | — |
![]() | M36 Underwater Obstacle Avoidance Sensor (Stainless Steel, Aviation Connector Version) M36 underwater obstacle avoidance sensor (stainless steel material, aviation plug version) | IP68 (pressure resistant to 150m) | -20~60 ℃ | 10.8V~26.4VDC, reverse polarity protection VDC | RS-485 (Modbus RTU protocol) | 0.3m / 0.4m / 0.1m / 0.05 m | -20~60 ℃ | 300K / 300K / 1MHz / 2MHz | 0.3~20m / 0.4~50m / 0.1~8m / 0.05~3 m | 151g (2m cable, direct outlet) / 114g (aviation plug type, net weight) / 94g (aviation plug type, net weight) / 90g (aviation plug type, net weight) g | — | 19.4°±1.9° / 10°±1° / 4.6°±0.5° / 2.1°±0.5 ° | <2000ms (software delay for protection) ms | 304 Stainless Steel | ±0.25 % | 4-core cable outlet / aviation plug outlet | Default 2m (other cable lengths require customization) m | — | 0.02m±0.5%D (D refers to the measured depth) | 140ms/time / 300ms/time / 115ms/time / 110 ms/次 | — | — |
![]() | Integrated Ultrasonic Level Meter (G1½ Thread, PVDF Material) | IP65 | — | — | — | — | — | — | — | — | 0.5%~1.0 % | — | — | — | — | — | — | 1mm or 0.1% (whichever is greater) | — | — | — | Display Instrument -20~+60°C, Probe -20~+80°C °C |
![]() | Handheld Depth Sounder S20 Pro+M36 Underwater Obstacle Avoidance Sensor (ABS Housing) Handheld Depth Sounder S20 Pro + M36 Underwater Obstacle Avoidance Sensor (ABS Housing) | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
![]() | Acoustic Doppler Current Profiler (ADCP) | IP68 at 10m Water Depth | — | — | — | — | — | 1MHz/2MHz | — | Approx. 1.5KG ±0.1kg (Cable Not Included) | — | — | — | — | — | — | — | — | — | — | — | -5°C ~ 60°C (Non-freezing) |
![]() | Dual-Probe Ultrasonic Open-Channel Flow Meter Dual-Probe Ultrasonic Open Channel Flow Meter | Display instrument IP65, probe IP68 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 1 mm | — | — | — | — |
![]() | Ultrasonic Sound Velocity Sensor Ultrasonic Sound Velocity Meter Sensor | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
![]() | M80 Underwater Obstacle Avoidance Sensor (Stainless Steel, with Aviation Connector) M80 Underwater Obstacle Avoidance Sensor (Stainless Steel Material, with Aviation Plug) | IP68 (Pressure Resistant to 150m) | -20~+60 ℃ | 10.8V~26.4VDC, Reverse Polarity Protection VDC | RS-485 (Modbus RTU Protocol) | 0.4m / 0.5 m | -20~+60 ℃ | 200K (Large Range) / 88 K | 0.4~200m / 0.5~300 m | — | — | — | <2000ms (Software Delay Protection) ms | Stainless Steel | 0.25%D (D Refers to the Measured Range) % | 4-Core Cable Outlet / Aviation Connector Outlet | Default 5m (Other Lengths Require Customization) m | — | 0.02±0.5%D (D Refers to the Measured Range) % | 50~65535ms/time (Adjustable) ms/次 | — | — |
![]() | Integrated Ultrasonic Level Meter (G2 Thread, ABS Material, with HART) Integrated Ultrasonic Liquid Level Meter (G2 Thread, ABS Material, with HART) | IP66 | — | — | — | 0.3-0.35 米 | — | — | — | — | 0.5%-1.0 % | — | — | — | — | — | — | 3 mm or 0.1% (whichever is greater) | — | — | — | Display Instrument -20~+60°C, Probe -20~+80°C ℃ |
![]() | IP68 Ultrasonic Water Level Meter (10-28V Power Supply, ABS Material, Bluetooth Communication) | IP68 | -20℃~60 ℃ | 10VDC~28 VDC | — | — | -40℃~80 ℃ | — | — | — | — | — | — | — | — | — | — | — | ±0.5%FS | — | — | — |
![]() | Integrated Ultrasonic Open-Channel Flow Meter (M48×2 Thread, PVDF Material) Integrated Ultrasonic Open Channel Flow Meter (M48×2 Thread, PVDF Material) | IP65 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 3mm or 0.1% (whichever is greater) | — | — | 0.36~99999.99m³/h, determined according to different weirs/flumes m³/h | — |
![]() | Integrated Ultrasonic Sludge Level Meter (M80 Depth Sounder, Stainless Steel) Integrated Ultrasonic Sludge Level Meter (M80 Depth Sounder, Stainless Steel Material) | IP68 | -20℃~+60℃ ℃ | DC10.8V~26.4V, reverse polarity protection V | RS-485 (Modbus RTU protocol) | — | -20℃~+60℃ ℃ | — | — | — | — | — | <2000ms ms | 304 stainless steel (316 stainless steel customizable) | 0.25%D (D = measured range) % | — | Default 5 m (custom lengths available) m | — | — | — | — | — |
![]() | Integrated Ultrasonic Sludge Level Meter (M80 Depth Sounder, ABS Material) | IP68 | -20℃~+60 ℃ | DC10.8V~26.4V, reverse polarity protection V | RS-485 (Modbus RTU Protocol) | 0.4m / 0.5 m | -20℃~+60 ℃ | 200kHz (Large Range) / 88 kHz | 0.4~200m / 0.5~300 m | 576g (5 m cable) / 1480g (5 m aviation plug) g | 0.02m±0.5% D (D refers to the measured range) | 8.7°±0.9% / 16.5°±10% ° | <2000 ms | ABS | 0.25%D (D refers to the measured range) | 4-core cable outlet / aviation plug outlet | Default 5 m (other cable lengths require customization) m | — | — | — | — | — |