Applications:Municipal wastewater sludge level monitoring, river silt thickness measurement<br>Industrial wastewater sludge-water interface detection, sedimentation tank sludge control<br>Accuracy: 1%–3%





| Function | (Split Type) |
|---|---|
| Range | 0.3~3m, special ranges can be customized |
| Measurement Accuracy | 1%~3 |
| Resolution | 5mm or 0.5% (whichever is greater) |
| Display | Chinese/English LCD display (on-site echo display) |
| Analog Output | 4~20mA / 510Ω load |
| Relay Output | Optional 2 or 4 SPDT (Single Pole Double Throw) relays; contact capacity: AC 250V/ (NO: 10A, NC: 6A) or DC 24V/10A |
| Supply Voltage | Standard 24VDC±10%; optional 90VAC~264VAC (50Hz/60Hz); customizable 12VDC±10% or battery powered |
| Operating Temperature | Display instrument: -20~+60℃, probe: -20~+80℃ |
| Communication | Interface: RS-485 or RS-232 optional; Protocol: Modbus RTU or manufacturer's custom protocol |
| Protection Rating | Display instrument IP65, probe IP68 |
| Probe Cable | Standard 10m, customizable up to 100m (provided there is no electromagnetic interference) |
| Installation Method | According to the range and probe model selection |
| Power Consumption of 24V-Powered Products | 24V split-type instrument, specific power as follows: with only 4~20mA output is 1.5W (standard); with only 485 output is 0.9W (optional); with both 485 and 4~20mA output is 1.6W (optional); for every additional 2 relay channels, power consumption increases by 0.8W on the original basis (optional) |
| Power Consumption of 220VAC-Powered Products | 220VAC split-type instrument power is 5 W |
| Output Type | 4-20mA/Relay |
Send us your working conditions — engineers reply with selection advice and pricing within 24 hours.