Dayu Electronics Ultrasonic Level Meter Bottom Thread Installation Guide (Part 1)
采购一体式超声波液位计固定式多普勒流量计超声波物位计大禹电子
Dayu ElectronicsUltrasonic Level Meter Bottom Thread Installation Guide:
For bottom thread installation of the Dayu Electronics ultrasonic level meter, it is recommended to use a plastic flange to connect the sensor. A plastic flange effectively reduces the impact of resonance on measurements.

Figure 1: Install a flange above the measured object

Figure 2: Place a gasket with the same inner diameter on the flange

Figure 3: Align the transducer with the flange hole

Figure 4: Insert the transducer into the flange hole