Dayu Electronics M45 Leak Detection Listening Device Applied to Municipal Water Supply Pipeline Leak Monitoring
Engineers working on pipeline monitoring and underwater noise detection all know that some working conditions sound simple, but once you actually get started, they're full of pitfalls:
Municipal water supply pipelines are buried deep underground. To install a leak monitoring sensor, you have to shut off water, cut openings, and weld — not only are construction costs high, but resident complaint calls come one after another;
Chemical plant pipeline surfaces are covered in rust. Ordinary sensors can't be strapped on or adhered securely — they fall off after just two days;
For underwater noise source localization, if sensor sensitivity is insufficient, weak signals simply cannot be captured, and localization is pure guesswork;
Ship/underwater equipment housings are sealed metal structures. To monitor equipment operating status, you can't cut openings without compromising housing seal integrity...
Ordinary hydrophones either have complicated installation, insufficient sensitivity, or inadequate protection ratings for humid environments. Searching the market, there aren't many options that can simultaneously deliver "rapid deployment" and "high-sensitivity listening."
Dayu Electronics M45 Leak Detection Hydrophone — dual-mode magnetic/collar mounting. Stick it on or strap it on and it's ready to "listen." IP68 fully waterproof, stainless steel housing. It gets the job done.

I. An "Underwater Long-Range Ear" Built for Rapid Deployment
The Dayu Electronics M45 Leak Detection Hydrophone is essentially a non-contact underwater acoustic sensor designed specifically for rapid deployment. It uses powerful magnets to directly attach piezoelectric ceramic elements to the metal outer wall of pipelines, tanks, or ship hulls — no cutting, no water shutoff, no complex installation required. It can "hear" internal water acoustic signals right through the metal.
This kind of "no cutting, no water shutoff, no complex installation" product can save you how much time and money.
Just as a doctor uses a stethoscope to listen to a heartbeat — the M45 presses tightly against the outer pipe wall, "listening" to internal water acoustic signals and passing them to the backend system for analysis and identification.
Its core component is a high-sensitivity piezoelectric ceramic transducer responsible for converting water acoustic signals into electrical signals. The acquired signals are processed by a built-in amplifier circuit and output via RS-485 or analog interface for analysis by a host computer or data acquisition system. The entire unit features a 304 stainless steel housing, with the complete cable assembly rated IP68. From sensor to signal output, the entire chain is hermetically sealed and reliable — impervious to humidity, corrosion, and underwater environments.

II. Three Core Advantages, Purpose-Built to Fix Every "Can't Hear It" Problem
Magnetic/Collar Mounting — No Water Shutoff, No Cutting
Traditional leak monitoring requires cutting into the pipeline and welding bases, which means shutting off water and lengthy construction periods at high cost. The M45 offers two mounting options: magnetic and collar clamp. On ferrous pipelines, one click and the magnet holds firmly; for surface-visible non-ferrous pipelines, securing with a collar clamp also requires no cutting or water shutoff — deployment takes just minutes.
One construction worker costs 500 RMB per day. If installation is completed in a manhole in just over ten minutes, that means how much labor cost savings?
High-Sensitivity Listening — Small Leaks Can't Escape
Sensitivity: ≥ -160 dB (Vref: 1V/μPascal), frequency response 20Hz ~ 20kHz.
A leak the size of a pen refill on a water supply pipe — can be captured;
Acoustic characteristics of liquid flow inside a pipe — can be distinguished;
Abnormal vibrations in underwater equipment — can be effectively identified.
Everything that should be heard — not a single one gets missed.
IP68 Waterproof + 304 Stainless Steel — Install It Outside and Forget It
Full-unit IP68 protection, 304 stainless steel housing. Humid municipal water well environments, outdoor rainstorm washing, long-term underwater submersion — no water ingress, no corrosion under normal use.
Power consumption ≤150mW (12VDC power supply) — runs on just a few batteries.

III. Core Specifications at a Glance
Parameter | Specification | Field Significance |
Sensitivity | ≥-160dB(Vre: 1V/μPascal) | A leak the size of a pen refill can be captured — no anomaly gets missed |
Frequency Response Range | 20Hz~20kHz | Covers the full audible frequency band — from low-frequency vibrations to high-frequency noise, everything is captured |
Output Method | RS-485 or analog (choose one) | Digital signal connects directlyPLCor to cloud platforms; analog signal is compatible with legacy systems — convenient however you connect |
Analog Output | ×10Output / ×100Output, 0~3.3VDC | Two-level selectable gain — both strong and weak signals can be matched to acquisition equipment |
ENTrigger Acquisition | 3.3V~5V | External trigger signal can be connected — operates only when needed, saving power and adding flexibility |
Supply Voltage | 6VDC~13VDC | Wide voltage input — vehicle batteries and industrial power supplies can be connected directly |
Overall Power Consumption | ≤150mW(12VDCpower supply) | Continuous operation with negligible power draw — ideal for24hour uninterrupted monitoring |
Housing Material | 304Stainless Steel | Corrosion-resistant, rust-proof — suitable for outdoor and humid environments |
Protection Rating | Complete unit with cable ratedIP68 | Works normally even with long-term submersion |
Weight | ≤800g(including2mcable) | Lightweight design — magnets hold securely, no detachment under its own weight |
Dimensions | Length85mm, diameter54mm | Compact size takes up no space — installs even in narrow pipe galleries |
Mounting Method | Magnetic / Collar clamp | One click on ferrous pipes and the magnet holds; non-ferrous pipes secured with collar clamp — adapts to various pipe diameters |

IV.Your Working Conditions M45What it Can Do for You
Municipal Water Supply Pipeline Leak Monitoring | Stick it on the outer wall — no water shutoff, no cutting,24hour leak sound monitoring |
Chemical Plant Liquid Pipeline Monitoring | Secure with collar clamp, works normally in humid environments |
Underwater Noise Source Localization | High sensitivity captures weak signals — know exactly where the noise comes from at a listen |
Ship//Underwater Equipment Status Monitoring | Magnetic or collar mount on exterior without compromising the housing — listen to internal operating sounds to detect anomalies |
Pipeline Liquid Flow Monitoring | Real-time listening to flow acoustic signatures — early detection of anomalies |
When evaluating equipment, first check whether installation is hassle-free, then whether signals can be captured reliably — the M45 magnetic-mount hydrophone: stick it on and it's ready to "listen."

V. About Dayu Electronics
Since its founding in 2008, the company has been dedicated to the R&D and industrialization of ultrasonic technology. From transducers to software and hardware, everything is independently developed. Products have been widely applied in meteorological monitoring, marine environments, industrial measurement and control, and other fields.
If you're struggling with pipeline leak monitoring or underwater listening challenges, why not hand the problem to Dayu?
Forwarding Copy: Whether a pipe is leaking — one listen tells you. Dayu Electronics M45 Magnetic-Mount Hydrophone — stick it on and it's ready to "listen." No water shutoff, no cutting, high sensitivity captures faint leak sounds. Click the article to see how it saves you effort →